Specification
1/0-1/0-1/0-1/0 Shetland Aluminum Quadruplex Overhead Service Drop Cable
Application:
Used to supply 3 phase power, usually from a pole- mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75 ºC for polyethylene insulated conductors or 90 ºC for crosslinked polyethylene (XLP) insulated conductors.
Also Know As:
1/0-1/0-1/0-1/0 Shetland Aluminum quadruplex, 1/0-1/0-1/0-1/0 Shetland overhead service drop, 1/0-1/0-1/0-1/0 Shetland three-phase cable, 1/0-1/0-1/0-1/0 Shetland 3 phase cable, 1/0-1/0-1/0-1/0 Shetland 3 phase power cable, 1/0-1/0-1/0-1/0 Shetland 3 phase extension cord, 1/0-1/0-1/0-1/0 Shetland 3 phase aluminum cable, 1/0-1/0-1/0-1/0 Shetland 3 phase electrical cable, 1/0-1/0-1/0-1/0 Shetland three-phase power cable, quadruplex wire, 1/0-1/0-1/0-1/0 Shetland quadruplex overhead wire, 1/0-1/0-1/0-1/0 Shetland overhead service entrance cable.
Construction:
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201 alloy. One conductor is manufactured with an extruded ridge for phase identification.
Standards:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
B-231 Aluminum conductors, Concentric-Lay-Stranded.
B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474
Specification:
• Phase Conductor Size/AWG: 1/0
• Phase Conductor Stranding: 19/w
• Phase Conductor Insulation ThicknessL: 60 mls
• Bare Neutral Messenger Size/AWG: 1/0
• Bare Neutral Messenger Stranding: 7
• Bare Neutral Messenger Breaking Strength: 4460 Lbs
• Weight Per (lb/1000 ft) XLP: 546 Lbs
• Weight (lb/1000 ft) Poly: 521.1 Lbs
• Ampacity XLP: 180 Amps
• Ampacity Poly: 140 Amps