Indoor/Outdoor Optical Cable 12 Fiber 62.5/125 12 Fiber SingleMode Black Riser Cable DX024DZCI9KR
Where are we? 4 Continents 9 Countries

Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
Product Information
Specification
| Tensile Load | Menimum Bend Radius | ||||||
| Diameter | Weight | Installation | Operational | Installation | Long Term | ||
| Fiber Count | Part Number | mm/(in) | kg/km (lbs/1,000) | N (lbs) | N (lbs) | cm (in) | cm (in) |
| 24 | DX024DZCI9KR | 8.9 (0.35) |
66.0 (46.20) |
3,000 (670) |
1,000 (220) |
13.4 (5.3) |
8.9 (3.5) |
APPLICATIONS:
• Indoor/Outdoor tight-buffered design allows cables to be installed in intra-building backbone and inter-building campus locations without costly transitions between cable types
• Ideal configuration for a single termination point requiring multiple fibers
• 900μm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices, because connectors terminate directly to the fiber
• No need to splice outdoor cable to indoor cable at building entrance
• High crush resistance may eliminate the need for innerduct
COST SAVINGS:
• 900 µm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber
• No need to splice outdoor cable to indoor cable at building entrance
• High crush resistance may eliminate the need for innerduct
STANDARDS:
Optical Cable Corporation's Indoor/Outdoor tight-buffered fiber optic cables meet the functional requirements of the following standards:
• UL 1651
• UL 1666
• GR-409-CORE
• ICEA-S-104-696
• ICEA-S-83-596
• TIA-568
• TIA-598
• UL-listed type OFNR in accordance with NEC sections 770-179 (B) and 770-154 (B) for use in vertical runs in building riser shafts or from floor to floor. Meets or exceeds requirements for intra-building fiber optic cables as outlined in GR-409-CORE.
CHARACTERISTICS:
| Characteristic | Riser |
| Operating Temp | -40°C to +85°C |
| Storage Temp | -55°C to +85°C |
| Install Temp | -10°C to +60°C |
| Flame Retardancy | UL listed type OFNR (UL 1666) for all fiber counts *FT4 (CSA C22.2 No. 232) for 2-24 fiber counts only |
| Crush Resist | 1800 N/cm |
| Impact Resist | 1500 impacts |
| Flex Resist | 2000 cycles |
| Jacket Type | D |
FEATURES:
• High performance components and construction
• Cable materials are indoor/outdoor - UL-listed OFNR and UV, water and fungus resistant
• UL Listed in accordance with NEC section 770.179(b) for use in vertical runs in building riser shafts or from floor to floor
• Wide operating temperature range of -40°C to +85°C
• Helically stranded core for greater flexibility and mechanical protection of the optical fibers
• High strength-to-weight ratio
• 2-144 fiber configuration is smaller and lighter than comparable sub-grouped cables made by others: ideal for installation in areas with limited space or tight bends
• Can be armored for additional protection in direct burial and aerial installations
• Interlocking armor can be applied to cables as an alternative to conduit installation
Download PDF Spec Sheet
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460