350 Type UL MV105 Shielded EPR Insulation PVC Jacket 133% Insulation Copper Power Cable 15KV
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
350 TYPE UL MV105 SHIELDED EPR INSULATION PVC JACKET 133% INSULATION COPPER POWER CABLE 15kV
Allowable Ampacity for 350 MCM TYPE UL MV105 SHIELDED EPR INSULATION PVC JACKET 133% INSULATION COPPER POWER CABLE 15kV at 105°C (In Duct): 415 Amps
Allowable Ampacity for 350 MCM TYPE UL MV105 SHIELDED EPR INSULATION PVC JACKET 133% INSULATION COPPER POWER CABLE 15kV at 105°C (In Air): 610 Amps
Applications:
The mv105 copper cable is an electrical wire used for power circuits up to 15,000 Volts when fixed in open air, conduit, or duct; in applications such as chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations, and generating stations. The National Electric Code accepts this electrical cable for uses within 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions.
Also Known As:
350 mcm medium voltage power cables, 350 mv power cable, 350 mv105 cable, 350 mv105, 350 pvc jacket, 350 erp power cable, 350 mcm mv power cable, 350 mcm mv105 cable, 350 mcm mv105, 350 mcm pvc jacket, 350 mcm erp power cable.
Standards:
- ICEA S-93-639
- NEMA WC74
- AEIC CS8
- Federal Specification J-C-30B
Construction
Conductors:
The MV power cable conductor is made of copper and has a conductor shield with soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed), or ASTM B-496 (compact).
Insulation:
A strong and enduring ethylene-propylene rubber (EPR) is used as the insulation system. The good thing about this insulation is how friendly it is to human hands since it is a rubber, a material that tends to be soft but guarantees profound and reliable safety wires. This insulation is also environmentally friendly, it doesn’t contain any toxins which can cause harm to human, animals, and plants health.
Shield:
Uncoated copper tape with a minimum 12.5% overlap per ICEA S-97-682.
Jacket:
Reinforced insulation is provided by a PVC jacket, which is sunlight-resistant, per ICEA S-97-682 and UL Standard 1072.
Specifications:
- Conductor Size AWG: 350
- Insulation Thickness (mils): 220
- Conductor Diameter (inches): 0.622
- Insulation Diameter (inches): 1.11
- Insulation Shield Diameter (inches): 1.16
- Jacket Diameter (inches): 1.32
- Net Weight (Lbs/1000FT): 1676
- Ampacity @ 105°C (In Duct): 415 Amps
- Ampacity @ 105°C (In Air): 610 Amps
Compatible with Manufacturer |
|
Houston Wire & Cable : | HW20835001 |
Omni Cable : | MVE335001 |
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet
Reviews