10 AWG 9C Unshielded Tray Cable XLPE Insulation PVC Jacket 600V E2
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
10 AWG 9C Unshielded Tray Cable XLPE Insulation PVC Jacket 600V E2
Applications:
Primarily used for power, control, signal, communication and lighting circuits in commercial and industrial environments. Suitable for installation in cable trays, supported by messenger in open air, raceways, channels, conduits and ducts. Approved for direct burial applications and outdoors in cable tray where sunlight resistant rating is required. Also may be installed in wet or dry locations or in areas exposed to chemicals and oils.
Also Known As:
10 AWG 9C Cable Tray, 10 AWG 9C Cable Tray Types, 10 AWG 9C Electrical Cable Tray, 10 AWG 9C Pvc Cable Tray, 10 AWG 9C wire cable tray, 10 AWG 9C cable tray wire, 10 AWG 9C Tray Instrument Cable, 10 AWG 9C Tray Instrumentation Cable, 10 AWG 9C TC-ER Cable, 10 AWG 9C direct burial tray cable, 10 AWG 9C EPR Cable, 10 AWG 9C CPE Cable, 10 AWG 9C Exposed Run Tray Cable, 10 AWG 9C XHHW tray cable,10 AWG 9C XHHW tray wire,10 AWG 9C tinned copper tray cable, 10 AWG 9C Chlorinated Polyethylene cable, 10 AWG 9C Ethylene Propylene Rubber cable, 10 AWG 9C flame-retardant tray cable, 10 AWG 9C tray power cable, 10 AWG 9C tray control cable, 10 AWG 9C FREP cable.
Standards:
• UL Listed as TC-ER (Exposed Run) per UL Standard 1277 and used in accordance with NEC for 3 or more conductors.
• Approved for Class 1 or 2, Division 2 industrial hazardous locations per NEC
• Individual conductors pass UL VW-1 flame test and rated XHHW-2/VW1, UL 1581/UL 2556 VW-1
• Rated at 90°C wet or dry
• Oil Res I & II
• “Heavy Duty” rating per ICEA Standards
• Meets cold bend test at -25°C
• NEMA WC70/ICEA S-95-658, NEMA WC57/ICEA S-73-532
• IEEE 1202 and CSA FT4 70,000 BTU Flame Test
• IEEE 383 70,000 BTU Vertical Flame Test
• ICEA T-29-520 210,000 BTU
Conductor:
• Fully annealed bare copper per ASTM B-3, Class B stranding per ASTM B-8
Insulation:
• Flame retardant Cross-linked Polyethylene (FR-XLPE) that is heat and moisture resistant. Also has a VW-1 rating and is XHHW-2 per UL 44
Jacket:
• Flame and sunlight resistant black PVC rated 90°C wet or dry per UL 1277
Specification:
• Gauge: 10 AWG
• No. Conductors: 9
• No. of Strands: 7
• Insulation Thickness: 0.030 Inches
• Jacket Thickness: 0.060 Inches
• Overall Diameter : 0.780 Inches
• New Weight lb/1000FT: 465 Lbs
Manufacturer Equivalents |
|
Omni Cable : | A51009 |
Priority Wire : | 10-09TC-XLP |
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460