Aluminum EPR / LLDPE Concentric Neutral MV-90 Primary UD Cable 5 kV - 46 kV

Select a Gauge
Where are we? 4 Continents 8 Countries


Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
Aluminum EPR / LLDPE Concentric Neutral MV-90 Primary UD Cable 5 kV - 46 kV
Application:
• Underground primary residential and commercial distribution circuits.
• May be used in wet or dry locations, installed in underground ducts or direct burial.
Also Known As:
Aluminum EPR cable,High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable,EPR LLDPE cable, MV-90 primary UD 46 kV cable
Standards:
• ICEA S-94-649: Standard for Concentric Neutral Rated Cables 5 – 46 kV.
• AEIC CS8: Specifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.
Maximum operating voltage:
• 5 kV – 46 kV, 100 and 133% IL
Maximum conductor operation temperatures:
Wet and dry locations
• Normal: 105 °C
• Emergency: 140 °C
• Short Circuit: 250 °C
Construction:
• Conductor: Conductor: Soft annealed uncoated copper Class B compressed or unilay
compressed per ASTM B8 or hard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil.
• Conductor Shield: Semi conducting cross-linked polyethylene (XLPE).
• Insulation: Thermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.
• Insulation Shield: Semi conducting cross-linked polyethylene (XLPE).
• Concentric Neutral: Soft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.
• Jacket: Extruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.
Features:
• Low tension stripping compounds.
• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.
• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.
• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.
• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.
• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.
• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460