350 MCM HVTECK Aluminum 420 mil TRXLPE TS AIA 35kV 133% IL PVC Jacket CSA
Application:
The 35kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs /FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant Single Conductor, 420 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket
Also known as:
350 MCM HVTECK 35kV Aluminum TRXLPE Cable HVTECK 1/C 420 mil AIA Shielded PVC Cable 350 MCM HVTECK 35kV 133% Insulation Level Cable Aluminum Interlocked Armor 35kV Cable 350 MCM HVTECK 1/C AIA TRXLPE Shielded Cable 35kV 133% IL TRXLPE PVC Jacket Cable Aluminum Armored 35kV Medium Voltage Cable 350 MCM HVTECK 35kV Cable with PVC Jacket CSA 1/C 35kV TRXLPE Aluminum Jacketed Cable.
Construction:
Conductor:
Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836
Conductor Shield:
Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil
Insulation:
420 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level
Insulation Shield:
Strippable semi-conducting cross-linked copolymer
Copper Tape Shield:
Helically wrapped 5 mil copper tape with 25% overlap
Inner Jacket:
PVC inner jacket
Armour:
Aluminum Interlocked Armour (AIA)
Overall Jacket:
Black Polyvinyl Chloride (PVC) Jacket
Standards:
• ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy
• ASTM B836 Compact Rounded Stranded Aluminum Conductors
• CSA C22.2 No. 174 Cables in Hazardous Locations
• CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods
• CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
• CSA C68.3 Shielded & Concentric Neutral Power Cable - 5 to 46 kV
• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating
• CSA HL - for Hazardous Locations rating
• CSA SUN RES - for Sunlight Resistant rating
• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
• ICEA T-29-520 Flame Test (210,000 BTU/Hr)
• IEEE 383 Flame Test (70,000 btu)
• IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test (1/0 and Larger)
Specification:
• Size: 350 MCM
• Number of Strands: 37
• Diameter Over Conductor (inch): 0.615
• Diameter Over Insulation (inch): 1.501
• Insul Thickness: 420
• Diameter Over Insulation Shield: 1.561
• Jacket Thickness (mil): 110
• Dia. Over Armour: 2.157
• Overall Jacket Thickness: 60
• Approx. OD (In): 2.277
• Approx. Weight (Lbs/1000'Ft): 2274
• DC Resistance @ 25°C Ω /1000ft: 0.050
• AC Resistance @ 90°Ω /1000ft: 0.065
• Allowable Ampacity In Air 90°C: 443
• Allowable Ampacity Directly Buried 90°C: 399