Got any questions? Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313
Text Us: 1-516-703-3460
Live Chat: Look Bottom Right
Email: sales@nassaunationalcable.com
Quick Support
Select a Gauge
Categories: Renewaflex bess class k type rhh xlpe power cables 2000v
Enter the required footage in the quantity box - Cut to one length
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Live Chat: Bottom Right Corner!
info@nassaunationalcable.com
2 AWG Renewaflex BESS Class K Type RHH XLPE Power Cables 2000V
Also Know As:
2 AWG Renewaflex Cable, 2 AWG BESS Cable, 2 AWG XLPE Power Cable, 2 AWG Class K Cable For Battery, 2 AWG Cables for Battery Energy Storage Systems, 2 AWG Type RHH Cables.
Applications:
Southwire’s 2000 Volt power cables are suited for use in the internal wiring of Battery Energy Storage Systems (BESS), in wet and dry locations, conduits, ducts, troughs, covered trays, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation, 130°C for emergency overload, and 250°C for short circuit conditions. Gasoline and Oil Resistant. For CT USE sizes 1/0 AWG and larger. Rated 1000 lbs./FT maximum sidewall pressure.
Conductor: 6 - 4/0 AWG: Class K, Flexible stranded bare copper. 250 - 750 kcmil: Class I, Flexible stranded bare copper
Insulation: Cross Linked Polyethylene (XLPE) Type RHH/RHW-2
Specification:
• ASTM B3 Soft or Annealed Copper Wire• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having • • Bunch-Stranded Copper Conductors• UL 44 Thermoset-Insulated Wires and Cables• UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test• RoHS-3 Complies with European Directive 2015/863• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661 • REACH - European Community Regulation
Cond Size: 2Strand Number: 665Diameter over conductor Inch: 0.302Insul. Thickness: 70Approx. OD inch: 0.448Approx. Weight 1000FT : 252 LBSMin Bending Radius: 3.5Max Pull Tension: 531DC Resistance @ 25°C: 0.165AC Resistance @90°C: 0.207Inductive Reactance@ 60Hz: 0.045Allowable Ampacity In Air 90°C: 190Allowable Ampacity In Raceway 90°C: 130
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460