268-20-5504 16 AWG 4T Nickel Coated Copper Shield Al Mylar TPPO Okothe

Items in Cart ()

View cart

268-20-5504 16 AWG 4T Nickel Coated Copper Shield Al Mylar TPPO Okotherm CIC P-OS 600V Instrumentation Cable

268-20-5504 16 AWG 4T Nickel Coated Copper Shield Al Mylar TPPO Okotherm CIC P-OS 600V Instrumentation Cable
Roll over image to Zoom

268-20-5504 16 AWG 4T Nickel Coated Copper Shield Al Mylar TPPO Okotherm CIC P-OS 600V Instrumentation Cable

SKU: 268-20-5504

Select a Gauge

268-20-5504 16 AWG 4T Nickel Coated Copper Shield Al Mylar TPPO Okotherm CIC P-OS 600V Instrumentation Cable
Price:
Regular price
$0.00 /Qty
Sale price
$0.00 /Qty
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

268-20-5504 16 AWG 4T Nickel Coated Copper Shield Al Mylar TPPO Okotherm CIC P-OS 600V Instrumentation Cable

Allowable Ampacity for 268-20-5504 16 AWG 4T Nickel Coated Copper Shield Al Mylar TPPO Okotherm CIC P-OS 600V Instrumentation Cable:100 Amps

About:

The 268-20-5504 16 AWG 4T Nickel Coated Copper Shield Al Mylar TPPO Okotherm CIC P-OS 600V Instrumentation Cable featuring a nickel-coated copper shield, aluminum Mylar tape, and TPPO insulation. It's designed for industrial control systems, power generation, and chemical plants, providing reliable signal transmission and protection against electrical interference. This cable meets key UL, IEEE, CSA, ICEA, and ASTM standards.

Also Known As:

16 AWG Nickel Coated Copper Shielded Instrumentation Cable
600V Okotherm Instrumentation Cable

Application:

Okotherm CIC 600 volt instrumentation cables are used in systems where, in the event of a fire, circuit integrity is required in order to maintain a process or to safely shut down the process. Fire resistance is determined by compliance to the IEC 60331 circuit integrity fire test. Okotherm CIC cables maintain circuit integrity based on qualification to IEC standard 60331, for all temperatures and times up to and including 2000°F for three hours. When exposed to a fire, the Okotherm CIC insulation becomes an, electrically insulating ceramic-like ash that is capable of maintaining the operating voltage. The overall shield eliminates most of the static interference from the electric field radiated by power cables and other electrical equipment.Okotherm CIC 600 volt instrumentation cables should be considered on circuits designed for fire detection and suppression, alarms, communication, circuits requiring redundancy and personnel egress

Standards:

• UL 1277: Standard for Electrical Power and Control Tray Cables with Optional Optical-Fiber Members.
• UL 1685: 
Standard for Vertical-Tray Fire-Propagation and Smoke-Release Test for Electrical and Optical-Fiber Cables.
• IEEE 1202/FT4: 
Standard for Flame Test for Cables for Use in Cable Tray in Industrial and Commercial Occupancies.
• CSA C22.2 No. 230: 
Standard for Tray Cables.
• ICEA S-73-532/NEMA WC57: 
Standard for Control, Thermocouple Extension, and Instrumentation Cables.
• ASTM B355: 
Standard Specification for Nickel-Coated Soft or Annealed Copper Wire.
• IEC 60502-1: 
Standard for Power Cables with Extruded Insulation and Their Accessories for Rated Voltages from 1 kV (Um = 1.2 kV) up to 30 kV (Um = 36 kV).

Construction:

• Conductors: Class B stranded nickel coated copper.
• Insulation: 
Okotherm Thermoset Silicone, with FR tape if required.
• Braid: 
Fiberglass Braid
• Color Code:
 ICEA S-73-532, Method 7
• Assembly: 
Pairs or triads assembled with left hand lay. Fiberglass fillers included where required to provide a round Cable.
 Cable Shield: Aluminum-mylar tape overlapped to provide 100% coverage and a 7-strand nickel coated copper drain wire, same size as conductors.
• Jacket: 
Black Okoclear-TP (TPPO).

Features:

 UL listed Type TC-ER per E60422.
 Sunlight resistant.
  Passes UL 1277 vertical tray flame test.
 Passes IEEE 1202-1991 vertical tray flame test.
 Conforms with “LS” limited smoke requirements of UL 1277 (3 or more Type RHH insulated conductors) for sizes 14 AWG and larger.
 90°C continuous rating.
 130°C emergency overload rating.
 250°C short circuit rating.
 Individual pairs or triads are numbered and color coded for simplified hook-up.
 Good EMI shielding characteristics.
 Individual units are completely isolated for maximum noise rejection.
 Quality control inspected to meet or exceed applicable industry standards.
 Jacket resistant to moisture and most chemical atmospheres.
 Thermal stability at elevated temperatures.
 Easy to install and terminate.
 Mechanically rugged.
 Fire Resistant - Qualified to meet IEC 60331, -11 & -21, including temperature
and time up to 2000°F for 3 hours, respectively.
 Fire Resistant - Qualified to meet the Hydrocarbon Pool Circuit Integrity Fire Test, utilizing the UL 1709 timetemperature curve, with minimum requirements of 65,000BTU/h-ft2 heat flux, 2000°F flame temperature, 30 minute test duration, and 15A load.

Specifications:

Conductor Size AWG/kcmil: 16(7X)
• Number of Triads
:
4

• Jacket Thickness-mils: 80
• Nominal Cable O.D. - Inches: 1.07
• Cross-Sectional Area  (sq in): 0.90
• Approx. Net Weight: 564

• Part Number: 268-20-5504


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color

Download PDF Spec Sheet

Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460