709-07-4050 Okonite Communication Cable Underground Installation - 19
nassaunationalcable.com/collections/okonite-communication-cable-for-transit-systems/products/709-07-4050-okonite-communication-cable-underground-installation-19-awg-50-pairs

Items in Cart ()

View cart

709-07-4050 Okonite Communication Cable Underground Installation - 19 AWG - 50 Pairs

709-07-4050 Okonite Communication Cable Underground Installation - 19 AWG - 50 Pairs
Roll over image to Zoom

709-07-4050 Okonite Communication Cable Underground Installation - 19 AWG - 50 Pairs

SKU: NNC9858X
okonite-communication-cable-underground-installation
Min Length: 1 FT
Max Length: 10000 FT
Price:
Regular price
$0.00 /FT
Sale price
$0.00 /FT
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

Insulation

Polyolefin compound color coded per U.S. telephone industry standards with color concentrates chosen for permanency and electrical balance of individual circuits

Pairs, Assemby and Fill
Pairs: Insulated conductors twisted into pairs of specified color combinations to provide pair identification as well as low susceptibility to noice pick-up, and with varying lay lengths to minimize crosstalk.
The average pair lay length is limited to 6 inches (15cm) to avoid split pairs in field splicing or circuit rearrangements
Core Assembly: airs assembled, as required by pair count and geometry, into concentric sub-units of less than 25 pairs, concentric 25 pair units, and 50 or 100 pair super-units, which are then formed into cable core in such a manner as to avoid parallelism of like twist pairs in outside layers of adjacent units for control of unit to unit crosstalk and to ensure cable flexibility as well as circular core with uniform distribution of pairs.
Each 25-pair group in the cable core is identified by color coded non-hygroscopic binders.
Cable Core Fill: A petroleum jelly base multi-component filling compound completely fills the cable core space between insulated conductors and between the core and the core wrap including the core wrap tape overlap. The filling compound is especially designed to prevent moisture or water entry and migration transversely and longitudinally in the cable core. High immunity to moisture and water penetration is enhanced through high adhesion and cohesive properties of the compound.
Core Wrap: A non-hygroscopic polymeric tape applied with overlap over the cable core to ensure high dielectric strength from cable core to shield, enhance mechanical properties of the cable, and provide thermal barrier for cable jacket extrusion operation. The space between the core tape and the inner jacket, is filled with specially formulated flooding compound which is designed to prevent moisture and/or water entry and migration.
Inner Jacket: Virgin. black, high molecular weight polyethylene copolymer jacket provides additional mechanical properties and dielectric strength between the cable core and the shield. The inner jacket also provides additional provides additional moisture or water ingress protection in case of outer jacket damage during cable installation or service.
Shield/Armor: (KTTG-F-B) 0.005 inch thick, corrugated bimetal tape, consisting of metallurgically bonded 0.8 mils Cu, 3.4 mils Fe and 0.8 mils Cu, applied longitudinally with overlap. Corrugations designed to enhance cable flexibility and to minimize shield/armor metal fatigue.
Outer Jacket: Virgin black, high molecular weight polyethylene copolymer jacket extruded overall. The jacket compound is selected for high resistance to abrasion, weathering, exposure to sunlight, temperature extremes, environmental stress cracking, and mechanical stresses encountered during cable installation and service. The jacket outer surface is sequentially marked at two-foot intervals with cable type, year of manufacture, footage, pair count, size, and manufacturer.
Shield/Armor: The bi-metallic shield/armor design makes the cables especially suitable for direct burial installations in gopher infested areas or in rocky terrain. The cables are totally filled to prevent moisture and/or water entry and migration during service life of the cables, and consequently assuring little, if any, change in transmission characteristics of Okonite€™s filled cables.
All cable components including insulation and filling compound are highly compatible with each other, assuring stability of electrical and physical properties of the cables within their expected 40-year service life.

Applications

Type KTTG-F-B filled cables are designed for exchange area or trunk service and are primarily intended for direct burial installation. These cables may also be used in underground duct installations.

Specifications

Conductor: Solid uncoated copper per ASTM B-3.
Insulation: Polyolefin per ICEA, REA PE-39. REA designation BFCY.
Jacket: Okolene (PE), meets or exceeds requirements of ICEA S-95-658, Part 4.1.6


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color

Reviews

Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460