163-23-6085 350 MCM 1C 37Strand Aluminum Shield Full Neutral 100% EPR Concentric BC PE Okoguard URO-J 35KV URD Cable
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
163-23-6085 350 MCM 1C 37Strand Aluminum Shield Full Neutral 100% EPR Concentric BC PE Okoguard URO-J 35KV URD Cable
Allowable Ampacity for 163-23-6085 350 MCM 1C 37Strand Aluminum Shield Full Neutral 100% EPR Concentric BC PE Okoguard URO-J 35KV URD Cable:100 Amps
About:
The Aluminum Shield Full Neutral 100% EPR Concentric BC PE Okoguard URO-J 35KV URD Cable is designed for underground residential distribution (URD) applications, providing reliable power transmission in residential areas.
Also Known As:
• URD Cable
• Aluminum URD Cable
Application:
• Okoguard URO-J cables provide maximum circuit longevity in underground residential distribution systems. They can be buried directly or installed in underground ducts or conduits
Standards:
• ASTM B-230: Aluminum 1350-H19 Wire for Electrical Purposes
• ASTM B-609: Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical Purposes
• UL Listed: Suitable for use under UL (Underwriters Laboratories) standards for electrical safety
Construction:
• Central Conductor: Aluminum per ASTM B609, Class B stranded per B-231.
• Filled Strand: Water swellable agent meets or exceeds ICEA T-31-610 water penetration resistance and ANSI/NEMA Class A connectorability requirements.
• Conductor Screen: Extruded semiconducting ethylene-propylene rubber meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.
• Insulation: Extruded Okoguard meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.
• Insulation Screen: Extruded semiconducting ethylene-propylene rubber meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.
• Concentric Conductor: Bare copper concentric wires helically applied.
• Jacket: Black Okolene with 3 red extruded stripes meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5 for polyethylene jackets.
Features:
• Triple tandem extruded, all EPR system.
• Okoguard cables meet or exceed ICEA standards.
• Meets RUS 1728.204 for cables with filled strand or solid conductor and 133% insulation level.
• Improved Temperature Rating. Okoguard insulation system has been tested and qualified for operation at 105°C continuous and 140°C emergency operating temperature.
• 250°C short circuit rating.
• Excellent corona resistance.
• Low dielectric constant and power factor.
• Screens are clean stripping.
• Exceptional resistance to "treeing".
• Moisture resistant.
• Excellent resistance to most chemicals.
• Can be listed by UL as Type MV-90 or MV-105 on special orders.
• CSA C68.5 listed, LTGG (-40°C), SR.
• Design Options:
• Triplexed or Paralleled
• Cable-in-Conduit
• Flat Strap Neutral
• Tinned Wires or Straps
• Water Blocking Powder or Tape
• Product identification via colored jackets
Specifications:
• Conductor Size AWG/kcmil: 350(37X)
• Nominal Dia. Over Insulation (in): 1.42
• Insulation Screen Thickness (miles): 40
• Nominal Dia. Over Insulation Screen (in): 1.52
• Copper Neutral No. x AWG (1): 18X.1078
• Nominal O.D (in): 1.91
• Approx. Net Weight: 2152
• 90°C Ampacity Direct Burial (2): 410
• 90°C Ampacity Duct (2): 320
• 105°C Ampacity Direct Burial (2): 445
• 105°C Ampacity Duct (2): 350
• Part Number: 163-23-6085
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460