1/0 AWG 3C MV105 15KV EPR/PVC Power Cable
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
1/0 AWG 3C MV105 15KV EPR/PVC Power Cable
Allowable Ampacity for 1/0 AWG 3C MV105 15kV EPR/PVC Power Cable (Conduit): 215 Amps
Allowable Ampacity for 1/0 AWG 3C MV105 15kV EPR/PVC Power Cable (Duct): 240 Amps
Applications:
The mv105 copper cable is an electrical wire used for power circuits up to 15,000 Volts when fixed in open air, conduit, or duct; in applications such as chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations, and generating stations. The National Electric Code accepts this electrical cable for uses within 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions.
Also Known As:
1/0 awg medium voltage power cables, 1/0 mv power cable, 1/0 mv105 cable, 1/0 mv105, 1/0 erp power cable, 1/0 awg mv power cable, 1/0 awg mv105 cable, 1/0 awg mv105, 1/0 awg erp power cable.
Standards:
- Industry: National Electrical Code (NEC). UL 1072. ICEA S-93-639/NEMA WC74. ICEA S-97-682. AEIC CS8. UL listed as type MV-105 for use in accordance with the NEC. Sizes 1/0 AWG and larger are listed and marked "Sunlight-Resistant FOR CT USE" in accordance with NEC.
- Flame Test: UL 1685 (70,000 BTU/hr)
- Optional Flame Test: IEEE 1202 (70,000 BTU/hr)/CSA FT4. ICEA T-29-520 (210,000 BTU/hr.)
- Other: EPA 40 CFR, Part 261, for leachable lead content per TCLP. OSHA acceptable.
Construction
Conductors:
The MV power cable conductor is made of copper and has a conductor shield with soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed), or ASTM B-496 (compact).
Insulation:
A strong and enduring ethylene-propylene rubber (EPR) is used as the insulation system. The good thing about this insulation is how friendly it is to human hands since it is a rubber, a material that tends to be soft but guarantees profound and reliable safety wires. This insulation is also environmentally friendly, it doesn’t contain any toxins which can cause harm to human, animals, and plants health.
Insulation Shield:
Thermoset semi-conducting polymeric layer free stripping from insulation.
Metallic Shield:
5 mil annealed copper tape with an overlap of 25%.
Jacket:
Reinforced insulation is provided by a PVC jacket, which is sunlight-resistant, per ICEA S-97-682 and UL Standard 1072.
Specifications:
- Size AWG: 1/0
- Stranding: 19
- Insulation Thickness (mils): 220
- Jacket Thickness (mils): 110
- Nominal O.D. Over Insulation (inches): 0.85
- Nom. O.D. (inches): 2.26
- Grounding Conductor Size (AWG): 4
- Approx. Net Weight (Lbs/1000 ft.): 2965
- Copper Net Weight (Lbs/1000 ft.): 1343
- Ampacity (Conduit): 215 Amps
- Ampacity (Duct): 240 Amps
Compatible with Manufacturer |
|
Priority Wire & Cable : | 1/0-0315KVSEPG |
Omni Cable : | MVE31/003 |
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460