8-3C Stranded Copper Metal Clad UL Galvanized Steel THHN/THWN Insulation Interlocked Armored Cable

Where are we? 4 Continents 9 Countries


Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
Allowable Ampacity for 8-3C Stranded Copper Metal Clad UL Galvanized Steel THHN/THWN Insulation Interlocked Armored Cable: 100 Amps
Applications:
Suitable for commercial, industrial, and multi-residential applications. It can be used for branch circuits and feeder wiring-services for power, lighting, control, and signal circuits, and can be exposed or concealed. It can also be used in a variety of locations, including environmental air-handling spaces, open or messenger supported aerial runs, and dry locations. In addition, it meets safety standards for hazardous locations and applications requiring superior EMI shielding, including Class I & II Div. 2 and Class III, Div. 1 & 2 (as specified in NEC Articles 501, 502, 503, and 530) and Places of Assembly.
Also Known as:
AFC Cable, Steel Strip Cable, MC Steel Cable, Galvanized Cable, Metal Clad Cable, MC Cable, Interlocking Armor Cable, Galvanized Steel
Construction:
• Armor: Galvanized Interlocking Steel Strip
• Conductors: Stranded Copper
• Conductor Insulation: THHN/THWN
• Assembly Covering: Polypropylene Tape
• Neutral Conductor: White
• Grounding: One grounding means – may be insulated or bare
• Maximum Voltage Rating: 600V
• Maximum Temperature Rating: 90°C (dry)
Features & Benefits:
• Galvanized interlocking steel armor
• May be used with set-screw connectors UL listed for use with MC Cable
• Superior EMI shielding versus aluminum armor
• UL Classified for Through-Wall Penetrations
• Type MC Steel Metal Clad Cable is a traditional Type MC cable containing one or more copper grounding conductors; the armor is not an equipment grounding means.
References & Ratings:
• UL 83, 1479, 1569, 1581, 2556, File Reference E80042
• NEC 230.43, 300.22(C), 392, 396, 330, 501, 502, 503, 530, 504, 505, 518, 520, 530, 645
• Cable Tray Rated, install per NEC
• Federal Specification A-A–59544 (formerly J-C–30B)
• Meets all applicable OSHA and HUD Requirements
• UL Classified 1, 2, and 3 hour through (Fire) penetration product, R–14141
• Environmental Air-Handling Space Installation per NEC 300.22(C)
• Made in USA of US and/or imported materials
Specification:
• Size AWG: 8
• Number of Conductors: 3
• Ground Size AWG: 10 Stranded
• Approx. Armor O.D: 0.704 Inch
• Weight 1000ft: 432 Lbs
• 200' Coil Code: 1716-40-00
• 500' Reel Code: 1716-45-00
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460