LS E9HKT-025B01CA00 2 AWG Strand Cu Filled 1/3 Reduced Neutral Shield LLDPE 175mils Series E9JK 15kV 100% MV-90 Primary UD Cable

LS E9HKT-025B01CA00 2 AWG Strand Cu Filled 1/3 Reduced Neutral Shield LLDPE 175mils Series E9JK 15kV 100% MV-90 Primary UD Cable
Roll over image to Zoom

LS E9HKT-025B01CA00 2 AWG Strand Cu Filled 1/3 Reduced Neutral Shield LLDPE 175mils Series E9JK 15kV 100% MV-90 Primary UD Cable

SKU:

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

LS E9HKT-025B01CA00 2 AWG Strand Cu Filled 1/3 Reduced Neutral Shield LLDPE 175mils Series E9JK 15kV 100% MV-90 Primary UD Cable

Allowable Ampacity for LS E9HKT-025B01CA00 2 AWG Strand Cu Filled 1/3 Reduced Neutral Shield LLDPE 175mils Series E9JK 15kV 100% MV-90 Primary UD Cable: 100 Amps

Applicable Standards:

• Suitable for underground primary power applications
• For wet or dry locations
• For direct burial or in duct

Also Known as:

UD Cable, LS Cable, E9JK Cable, Primary UD Cable, LS E9JK Cable, E9JK UD Cable

Description:

The Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with tree-retardant cross-linked polyethylene (TR-XLPE), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.

Features:

• High dielectric strength
• Low moisture absorption
• Low dielectric loss
• Excellent resistance to treeing
• Jacket is sunlight-resistant
• Designed to operate continuously at a conductor temperature not exceeding
» 90°C for normal operations
» 130°C for emergency overload
» 250°C for short circuit

Specification:

AWG Size: 2
Concentric Neutral No. x AWG: 6 x 14
Insulation: Polyethylene (TR-XLPE)
Jacket: Polyethylene (LLDPE)
Nominal Conductor Diameter¹ in (mm): 0.280 (7.1)
Nominal Insulation Diameter¹ in (mm): 0.68 (17.3)
Nominal Jacket Thickness¹ in (mm): 0.055 (1.40)
Nominal Overall Diameter¹ in (mm): 0.98 (24.9)
Ampacity Underground Duct²: 162
Ampacity Direct Buried²: 224
Nominal Net Weight: 577 lbs/kft 
Part Number: E9HKT-025B01CA00


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.