LS E8JLR-B21B03CB00 750 MCM 3C Strand Bare Copper Shield PVC 220mils Series E8JLR 15kV 133% MV-105 Power Cable

Where are we? 4 Continents 8 Countries


Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
LS E8JLR-B21B03CB00 750 MCM 3C Strand Bare Copper Shield PVC 220mils Series E8JLR 15kV 133% MV-105 Power Cable
Allowable Ampacity for LS E8JLR-B21B03CB00 750 MCM 3C Strand Bare Copper Shield PVC 220mils Series E8JLR 15kV 133% MV-105 Power Cable: 100 Amps
Applicable Standards:
• In conduit, duct, free air, direct burial and raceways, primary installations include cable trays, and outdoor locations
• In wet or dry locations
• Approved for Class I, Div. 2 industrial hazardous locations per NEC
• Designed to operate continuously at a conductor temperature not exceeding
» 105°C for normal operations
» 140°C for emergency overload
» 250°C for short circuit
Also Known as:
MV-105 Cable, LS Cable, E8JLR Cable, Power Cable, LS E8JLR Cable, E8JLR Power Cable
Description:
The 3 Conductor MV-105 Power Cables consist of fully annealed bare copper Class B stranded conductors, covered with ethylene propylene rubber (EPR), copper tape shield, and black PVC jacket. These cables are used in industrial power circuits.
Features:
• Rated at 105°C wet or dry
• Excellent corona resistance
• High dielectric strength
• Low moisture absorption
• Low dielectric loss
• Excellent sunlight resistance
• For CT USE per UL® 1072
• Meets cold bend test at -35°C
• For direct burial applications
Specification:
AWG Size: 750 MCM
Number of Conductor: 3
Insulation: Ethylene Propylene Rubber (EPR)
Jacket: Polyvinyl Chloride (PVC)
Nominal Conductor Diameter¹ in (mm): 0.958 (24.3)
Nominal Insulation Diameter¹ in (mm): 1.478 (37.50)
Ground Wire AWG: 1/0
Nominal Jacket Thickness¹ in (mm): 0.140 (3.55)
Nominal Overall Diameter¹ in (mm): 3.610 (91.7)
Ampacity Conduit in Air²: 635
Ampacity Underground Duct³: 585
Ampacity Tray4: 745
Nominal Net Weight: 10978 lbs/kft
Part Number: E8JLR-B21B03CB00
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color