12 Pair 1.0 mm² JIS C 3410 250V RCOP(IS) Shipboard Flame Retardant Instrumentation Cable
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
12 Pair 1.0 mm² JIS C 3410 250V RCOP(IS) Shipboard Flame Retardant Instrumentation Cable
Allowable Ampacity For 12 Pair 1.0 mm² JIS C 3410 250V RCOP(IS) Shipboard Flame Retardant Instrumentation Cable : 100 Amps
Application Standard :
- • Design Guide : IEC 60092-350 & IEC60092-376
- • Flame Retardant : IEC60332-1
: IEC 60332-3 Category A (FA-Cables Only) - • Cold Bend/Impact : CSA 22.2 No. 03 (-40℃/-35℃) (Cold Type Only)
- • Rated Conductor Temperature : 90℃
Also Known As :
Shipboard Cable, JIS C 3410, RCOP(IS), Galvanized Steel, Marine Shipyard Cable, Asian Shipyard Cable, Marine Instrumentation Cable, Flame Retardant Cable, Twisted Pairs
Construction :
Conductor :
- • Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2
Insulation :
- • Code : R
- • EPR As Per IEC 60092-351
Twisting :
- • Two/Three Insulated Cores Shall Be Twisted Together To Form A Pair/Triad
Individual screen :
- • Code: (IS)
- • AL/PS tape + Tinned copper drain wire (0.75mm2 )
- • A suitable tape may be applied on the individual screen
Cabling :
- • Twisted pairs/triads shall be cabled
- • Flame retardant & non-hygroscopic fillers may be used
- • Suitable tape(s) may be applied on the cabled core
- • A Filler may be applied to obtain a circular Cable
Inner sheath :
- • Code : C
- • SE1 as per IEC60092-359
Armour :
- • Code : O
- • Braid of plain annealed copper wires
- • Coverage density is minimum 90%
Outer sheath :
- • Code : P
- • ST2 (PVC) as per IEC 60092-359
- • Outer sheath color : Grey (for Non-IS Type) or Blue (for IS Type)
Core identification :
- • Printed pair/triad number and Alphabet letter on the white insulation
- • ex) 4P : (1A, 1B), (2A, 2B), (3A, 3B), (4A, 4B)
- • 2T : (1A, 1B, 1C), (2A, 2B, 2C)
Specification :
- • No. Of Units : 12P
- • Conductor Nominal Area : 1.0 mm²
- • Conductor Strand : 7 / 0.43 No./mm
- • Conductor Dia. : 1.29 mm
- • Nominal Dia. Inner Sheath : 22.2 mm
- • Overall Diameter Nominal : 26.4 mm
- • Overall Diameter Tolerance : 1.4 ±mm
- • Conductor Resistance (at 20°C) (Max) : 19.3 Ω/km
- • Insulation Resistance (at 20°C) (Min) : 1,050 Ω/km
- • Cable Weight : 0.7761 lbs
*Data provided on this page is subject to change based on different manufacturers' variances