60 Core 0.75 mm² JIS C 3410 150/250V (FA-)TTYCYSLA Shipboard Flame Retardant Instrumentation Cable
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
60 Core 0.75 mm² JIS C 3410 150/250V (FA-)TTYCYSLA Shipboard Flame Retardant Instrumentation Cable
Allowable Ampacity For 60 Core 0.75 mm² JIS C 3410 150/250V (FA-)TTYCYSLA Shipboard Flame Retardant Instrumentation Cable : 100 Amps
Application Standard :
- Design Guide : JIS C 3410(2010)
-
Flame Retardant : IEC60332-1
: IEC 60332-3 Category A (FA-Cables Only) - Cold Bend/Impact : CSA 22.2 No. 03 (-40℃/-35℃) (Cold Type Only)
- Max. Rated Conductor Temperature : 70℃
Also Known As :
Shipboard Cable, JIS C 3410 Cable, TTYCYSLA Cable, Asian Shipyard Cable, Flame Retardant Cable, Annealed Copper Wire, Instrumentation Cable, Japenese Industrial Cable, Marine Shipyard Cable
Construction :
Conductor :
- Code : TT
- Stranded Plain Annealed Copper Wires As Per JIS C 3410(2010)
Insulation :
- PVC As Per JIS C3410(2010)
Twisting :
- Two Insulated Cores Shall Be Twisted Together To Form A Pair
Cabling :
- Twisted Pairs Shall Be Cabled
- Flame Retardant & Non-Hygroscopic Fillers May Be Used
- Suitable Tape(s) May Be Applied On The Cabled Core.
Common Shield :
- Code : SLA
- Screened By AL/PS Tape With Tinned Copper Drain Wire
- A Suitable Tape May Be Applied On The Common Shield
Sheath :
- Code : Y
- PVC As Per JIS C3410(2010)
Armour :
- Code : C
- Braid Of Galvanized Steel Wire(C)
- Coverage Density : Min. 90%
Paint :
- The White Paint Shall Be Painted Uniformly On The Steel Wire Braid
- In Case Of PVC Protective Covering Cable, Paint Isdispensable
Protective Covering :
- Code : Y
- PVC As Per JIS C3410(2010)
- Protective Covering Color : Black
- Any Other Color May Be Applicable When Purchaser Required.
Core Identification :
- Printed Pair Number And Alphabet Letter On The White Insulation
- ex) 4P : (1A,1B), (2A, 2B), (3A, 3B), (4A, 4B)
- 1T, 1Q Cable Shall Be Identified By The Black Number On The White Insulation
Specification :
- No. of Cores : 30P
- No. of Cores : 60
- Conductor Nominal Area : 0.75 mm²
-
Conductor Strand : 7/0.37 No./mm
- Conductor Dia. : 1.11 mm
- (FA-)TTYCYSLA Nominal Overall Dia. : 39.4 mm
- (FA-)TTYCYSLA Tolerance : 1.6 ±mm
- Conductor Resistance (at 20°C) (Max): 26.0 Ω/km
- Insulation Resistance (at 20°C) (Min): 20 ㏁ - km
- Cable Weight : 1.3335 Lbs
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460