Allowable Ampacity for Igus CAT9511001 24 AWG 4C Harting Connector RJ45 Bare Copper Shield TC Braid PUR Harnessed Ethernet CAT5 Cable: 100 Amps
Also Known as:
Control Cable, CAT5 Cable, RJ45 Cable, Ethernet CAT5 Cable, Flexible Cable, IGUS Cable, Continues-Flex Cable, Dynamic Cable, Flexing Cable, Flex Cable, Linear Motion Cable
Construction:
• Conductor: Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (according to DIN EN 60228)
• Conductor Insulation: Mechanically high-quality TPE mixture (According to bus specification)
• Conductor Construction: According to bus specification
• Conductor Identification: According to bus specification.
• Overall Shield: Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical.
• Outer Jacket: Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in e-chains®.
• Jacket Color: Red lilac (similar to RAL 4001)
Properties and Approvals:
• UV Resistance: Medium
• Oil Resistance: Oil-resistant according to DIN EN 50363-4-1
• Flame Retardant: According to IEC 60332-1-2, CEI 20-35, VW-1, FT-1
• Silicone-free: Free from silicon which can affect paint adhesion (according to PV 3.10.7 – status 1992).
• UL/CSA AWM: See data sheet for details
• NFPA 79: Following NFPA 79-2012 chapter 12.9
• EAC: Certified to no. TC RU C-DE. ME77.B.01218
• CTP: Certified to no. C-DE.PB49.B.00416
• Lead-free: Following 2011/65/EU (RoHS-II)
• CEI: Following CEI 20-35
• Clean room: According to ISO Class 1. Outer jacket material complies with CF240.02.24, tested by IPA according to standard 14644-1
• CE: Following 2014/35/EU
Specification:
AWG Size: 24
Number of Conductors: 4
Rated Cross Section: 0.25 mm²
Conductor: Bare Copper
insulation: TPE
Jacket: TPE
Outer Diameter: 0.28 inch
Copper index: 22.2 lbs/mft
Voltage: 50V
Impedance: 100 Ω
Weight: 39.6 lbs/mft
Part Number: CAT9511001
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460