Applications:
Used as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical
stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.
Also Known As:
20 AWG 7C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 20 AWG 7C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 20 AWG 7C JZ 600-Y PVC Control Cable JZ 600-Y PVC Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable
Technical Data:
PVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 / DIN EN 50525-2-51
Temperature range
Flexible -15°C to +80°C
Fixed -40°C to +80°C
Nominal voltage
AC U0/U 600/1000 V
Test voltage core/core
4000 V
Breakdown voltage
8000 V
Coupling resistance
at 30 MHz, approx. 250 Ohm/ km
Minimum bending radius
Flexible 10x Outer-Ø
Fixed 5x Outer-Ø
Cable Structure:
• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
• Core insulation: PVC acc. to DIN VDE 0207-363-3 / DIN EN 50363-3 (compound type TI2)
• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits
• Protective conductor: starting with 3 cores,
G = with protective conductor GN-YE, in the outer layer,
x = without protective conductor (OZ)
• Cores stranded in layers with optimal lay lengths
• Inner sheath: PVC
• Screen: braided screen of tinned copper wires, approx. coverage 85%
• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 / DIN EN 50363-4-1 (compound type TM2)
• Sheath colour: black (RAL 9005)
• Length marking: in metres
Properties:
• Resistant to: UV radiation, weathering effects
• Largely resistant to: oil, for details, see "Technical Information"
• For outdoor use
• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
Tests:
• Flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332- 1-2 / IEC 60332-1-2
• UV-resistant acc. to DIN EN ISO 4892-2
• Weather-resistant acc. to DIN EN ISO 4892-2
• Certifications and approvals: EAC
Notes:
• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
Specification:
• Size : 20 AWG
• No. cores x cross-sec. mm²: 7 G 0.5
• Outer Ø mm, approx: 10.9
• Cu factor per km: 79.0
• Weight kg/km, approx: 230.0
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460