7x4 mm² Stranded Bare Copper Unshielded PVC UV Rigid Gaalflex Tray 600 R Cable

7x4 mm² Stranded Bare Copper Unshielded PVC UV Rigid Gaalflex Tray 600 R Cable
Roll over image to Zoom

7x4 mm² Stranded Bare Copper Unshielded PVC UV Rigid Gaalflex Tray 600 R Cable

SKU: 32020F7T070A12
gaalflex-stranded-bare-copper-unshielded-pvc-uv-rigid-tray-600-r-cable

Select a Gauge

7x4 mm² Stranded Bare Copper Unshielded PVC UV Rigid Gaalflex Tray 600 R Cable
Price:
Regular price
$0.00 /Qty
Sale price
$0.00 /Qty
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

7x4 mm² Stranded Bare Copper Unshielded PVC UV Rigid Gaalflex Tray 600 R Cable

Allowable Ampacity 
for 7x4 mm² Stranded Bare Copper Unshielded PVC UV Rigid Gaalflex Tray 600 R Cable: 100 Amps

About:

The " 7x4 mm² Stranded Bare Copper Unshielded PVC UV Rigid Gaalflex Tray 600 R This cable is a type of tray cable, specifically designed for power and control applications. It is suitable for use in rigid, structured environments, such as cable trays, often found in industrial settings.

Also Known As:

• It might be commonly referred to as "Gaalflex UV Resistant Tray Cable" or Stranded Bare Copper Tray Cable."

Application:

• Industrial Power and Control Circuits: Used in industrial environments for connecting power supplies, machinery, and control units.
• Outdoor and Direct Burial Installations:
 Its UV resistance makes it suitable for outdoor applications, and it can be used in settings where the cable might be exposed to sunlight or harsh weather conditions.
• Cable Trays and Conduit Systems: 
Ideal for structured cabling in manufacturing plants, warehouses, and large commercial buildings.

Standards:

• Likely meets specific industry standards for tray cables, possibly including UL listings for safety and quality assurance.
• The "600 R" designation suggests a rating for up to 600 volts, suitable for robust industrial applications.

Construction:

• Conductor: stranded red copper conductor similar Cl. 2,acc. to ASTM B3 and class B,stranded acc. to ASTM B8
• Insulation: 
special PVC/Nylon compound: from 1 sqmm up to 1,5 sqmm: UL 62 type TFN from 2,5 sqmm: UL 83 Type Thhn/thwn-2
• Colour cores: 
Multiconductors: acc. to ICEA S-73-532 table E2 method 13/4 Conductors+ground Conductor:14 AWG up to 10 AWG,acc. to ICEA S-73-532 table E2 method 18 AWG and larger,acc. to ICEA S-73-532 method 4,black numbered
• Ground-Conductor insulation: 14 AWG up to 6 AWG:insulated green ground.4 AWG up to 750 MCM:uninsulatedacc. to UL 1277
• Stranding: construction 2x: cores parallel construction from 3 cores and overall: in layers + fillers: construction 3x+1G: cores twisted together + fillers:
• Wrapping: synthetic tape
• Ripcord:
 nylon ripcord under outer sheath
• Outer sheath: black (RAL 9005), special PVC oil and UV resistance compound, flame retardant acc. to UL 1277

Features:

• Type Thhn/thwn-2: UL type TC, 600, rated 90°C, wet and dry Lead Free, exposed runs (ER)*
• TC: UL Standard 1277
• wet and dry use
• cable for tray use
• UV resistance
• weather resistance, direct burial class I, Div. 2 (also Zone 2), and class II, Div. 2 hazardous location acc. to NEC 2008/2011, as for Class III. Div 1&2 hazardous locatiotion acc. to NEC 2011
• *Cables with 3 or more conductors are UL listed for exposed runs (ER) when installed in accordance with NEC 336.10
• *ground conductor standard for sections 3x...+1G...,on request green-ground conductors for other sections
• RoHS approval

Specifications:

• AWG No: 12
 No.of cores x cross section n x mm2:
7 x 4
• Outer-Ø ca.mm ± 10%: 12,7
• Copper weight kg/km: 269
• Nominal voltage: 600V
• Test voltage: 4 kV
• Temperature Range: up to +90°C: Fixed Laying:-- 25°C
• Min. bending Radius: Fixed laying: Section up to 2 inch (51 mm) outer Ø: Section over 2 inch (51 mm) outer Ø: 5 x d 6 x d During Installation pull-in: 8 x d
• Cable Weight approx kg/km: 330
• Part Number: 32020F7T070A12


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color

Download PDF Spec Sheet