1000' 10 AWG THHN THWN-2 Solid Copper Building Wire | Nassau Cable
nassaunationalcable.com/collections/best-sellers/products/1000-10-awg-thhn-thwn-2-solid-copper-building-wire

Items in Cart ()

View cart

1000' 10 AWG THHN THWN-2 Solid Copper Building Wire

1000' 10 AWG THHN THWN-2 Solid Copper Building Wire
Roll over image to Zoom
1000' 10 AWG THHN THWN-2 Solid Copper Building Wire
Roll over image to Zoom
1000' 10 AWG THHN THWN-2 Solid Copper Building Wire
Roll over image to Zoom
1000' 10 AWG THHN THWN-2 Solid Copper Building Wire
Roll over image to Zoom
1000' 10 AWG THHN THWN-2 Solid Copper Building Wire
Roll over image to Zoom
1000' 10 AWG THHN THWN-2 Solid Copper Building Wire
Roll over image to Zoom
1000' 10 AWG THHN THWN-2 Solid Copper Building Wire
Roll over image to Zoom
1000' 10 AWG THHN THWN-2 Solid Copper Building Wire
Roll over image to Zoom
1000' 10 AWG THHN THWN-2 Solid Copper Building Wire
Roll over image to Zoom
1000' 10 AWG THHN THWN-2 Solid Copper Building Wire
Roll over image to Zoom
1000' 10 AWG THHN THWN-2 Solid Copper Building Wire
Roll over image to Zoom

1000' 10 AWG THHN THWN-2 Solid Copper Building Wire

SKU: NNC215221
best-sellers

Select a Gauge

1000' 10 AWG THHN THWN-2 Solid Copper Building Wire

Availability: In stock

Price:
Regular price
$500.00
Sale price
$280.00 /Qty 44% off
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

10 AWG THHN THWN-2 Copper Solid Building Wire

THHN THWN-2 Copper Building Wire Allowable Ampacity in Duct: 30 Amps at 60ºC / 30 Amps at 75ºC / 30 Amps at 90ºC

Also Known As:

10  thhn, 10 awg thwn 2, 10 awg thhn, 10 solid thhn, 10 gauge solid wire, 10 copper wire, 10 awg solid copper wire, 10 awg Copper wire, 10 awg building cable, 10 awg conduit wire, 10 awg nylon wire, 10 awg construction cable, 10 awg thermoplastic-insulated copper wire, 10 awg THHN-PVC tray cable.

10 AWG THHN THWN-2 Applications:

THHN stands for thermoplastic high heat-resistant nylon. Known for versatility and durability, it is the most common type of building cable. The double marking THHN /THWN-2 indicates that the electrical wire is suitable for wet and dry conditions equally (The letter "W" means that it is water-safe). Additionally, the cable is resistant to corrosion, excessive dryness, and the impact of chemicals. The building wire is rated 90 degrees Celsius in both wet and dry locations. The electrical wire is rated at 600 V.

THHN Applications include:

  • Building Wiring: This encompasses everything from lighting circuits to outlets in homes, commercial buildings, and industrial facilities.
  • Conduit and Cable Trays: THHN is designed to be pulled through conduit, making it ideal for structured wiring systems in commercial and industrial settings. It's also commonly used in cable trays in industrial facilities.
  • Control Systems: THHN can be used for wiring control circuits, including those for machinery, HVAC systems, and other building automation components.
  • Machine Tool Wire: In manufacturing and industrial environments, THHN is commonly used to wire machine tools and equipment.
  • Large Appliances: THHN wires can be used for connections inside large appliances like ovens, ranges, and HVAC units.
  • Motor Connections: For connecting motors in both residential and commercial settings
  • Feeders and Branch Circuits: In electrical distribution systems, THHN wires can serve as both feeders (which extend from service panels to subpanels or major appliances) and branch circuits (which extend from panels to outlets, lights, or individual appliances).
  • Service Entrance: While specific SE cables exist for this purpose, THHN wires can also be used for service entrances when appropriately configured and protected.

Particular 10 AWG THHN Application Are:

  • Residential Appliances: Used for larger household appliances like certain electric ovens or water heaters.
  • Smaller HVAC Systems: Typically in residential or light commercial settings.
  • Residential Subpanels: Especially in situations where the subpanel serves only a portion of a home or an outbuilding.

10 AWG THHN THWN-2  Construction:

Conductor:

THHN THWN-2 conductors are constructed of annealed soft copper that follows ASTM B3 and ASTM B8 standards. 

Insulation:

The cable is insulated with a thermoset plastic jacket (PVC) that is flame-retardant, sunlight-resistant, lead-free, strong, and stable. Without being too bulky, it ensures that the cable can be used in harsh conditions. The jacket is color-coded in accordance with ICEA Method 4.

10 AWG THHN THWN-2  Standards:

  • ICEA S-73-532
  • UL 1277 (Resistant to flame, moisture, and sunlight)
  • UL 1581, UL 83, UL 1063 , UL 758
  • A-A59544
  • ASTM B3 and B8 conductor
  • ANSI/NFPA 70 for Safe Electrical Design and Installation
  • RoHS compliant
  • Safe For Commercial and Industrial Use
  • Color-coded #1-E2 per ICEA S-73-532
  • May be used in NEC Class I and II systems
  • May be used in Division 2 hazardous locations
  • Allowed for Exposed Run (ER) and be used in accordance with NEC

10 AWG THHN THWN-2  Specifications:

  • Size AWG: 10
  • Outside Diameter: 3.78 mm / 0.149 inches
  • Cross Section Area:  5.26 mm2
  • Conductors: Annealed Soft Copper per ASTM B3 and ASTM B8
  • Stranding: Solid
  • Insulation: PVC
  • PVC Insulation Thickness: 3.78 mm / 0.149 inches
  • Nylon Thickness: 0.100 mm / 0.004 inches
  • Jacket: PVC
  • Weight (lbs/1000ft) : 39

            Manufacturer Equivalents

            Alan : 

            Black : 10NS15
            White : 10NS25
            Red : 10NS35

            Blue : 10NS45
            Green : 10NS55

            Orange : 14NO85
            Gray : 10NS95

            Nexans : Black : 616474
            White : 616482
            Red : 616490

            Blue : 616508
            Green : 616516

            Orange : 616292

            Gray : 618942

            Omni Cable :

            Black : M510SO-01
            White : M510SO-02
            Red : M510SO-03
            Green : M510SO-04
            Blue : M510SO-05
            Gray : M510SO-06
            Orange : M510SO-07
            Green / Yellow : M510SO0408

            Southwire :

            Black : 11595601
            White : 11596401
            Red : 11597201
            Blue : 11598001
            Green : 11599801

            Orange : 22961706
            Gray : 22982301


            *Data provided on this page is subject to change based on different manufacturers' variances
            ** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
            In the case the material only comes in a predetermined color or doesn’t come with any color

            Download PDF Spec Sheet

            FAQ's

            What does THHN stand for?

            THHN stands for "Thermoplastic High Heat-resistant Nylon-coated."

            What is THHN Wire suitable for?

            THHN wire is suitable for electrical conduits, indoor and outdoor use (as long as ranked THWN), building wire across industries, and control circuits.

            Does THHN Have to Be in Conduit?

            Yes, THHN has to be installed in conduit at all times as per NEC. The only exception to this rule is when THHN is installed in control panels.

            Can THHN Be Direct Buried?

            THHN does not have an appropriate rating for direct burial because of its construction, but THHN/THWN-2 with a double rating can.

            Is THHN Rated for Wet Locations?

            THHN is rated for dry locations, while THWN is rated for wet locations.

            Can THHN Be Used in Underground Conduit?

            The wire used for the underground conduit should have a THWN-2 rating for wet locations.

            Can You Run THHN in Walls?

            You can run THHN wire in walls within conduit or raceway, but NM-B wire is generally a more popular option for indoor wiring.

            Can you use THHN wire for automotive?

            Using THHN wire for automotive applications is not recommended.

            Is THHN wire waterproof?

            THHN/THWN is not waterproof. While it is suited for damp environments, it cannot be directly submerged in water.

            How many #10 THHN in 3/4 EMT?

            The NEC allows a maximum fill of 40% for more than two conductors in a conduit. For #10 THHN wires in 3/4" EMT, you can fit up to 10 wires.

            How many #10 THHN in 1 EMT?

            You can fit up to 16 #10 THHN wires in a 1" EMT conduit.

            How many #10 THHN in 1/2 EMT?

            For #10 THHN wires in 1/2" EMT, you can fit up to 5 wires.

            How many #10 THHN in 1 EMT?

            You can fit up to 16 #10 THHN wires in a 1" EMT conduit.

            Reviews

            Customer Reviews

            Be the first to write a review
            0%
            (0)
            0%
            (0)
            0%
            (0)
            0%
            (0)
            0%
            (0)
            Get in Touch
            Live Chat Get replies right away!
            Email info@nassaunationalcable.com

            Call Us: 1-516-482-6313    Text Us: 1-516-703-3460