Belden 9392 18 AWG 15 Pairs TC E2 PLTC-ER High Performance Instrumentation Cable
Applications:
This Belden Multi Pair High Performance Instrumentation PVC Jacket PLTC-ER cable is an electrical wire designed for power-limited circuits. The target applications of this cable are control and energy management systems in industrial installation sites, alarm and audio applications.
Also Known As:
18 awg belden wire, 18 awg belden cable, belden instrumentation cable, belden instrumentation wire, belden high-performance wire, belden high-performance cable.
Standards:
-
Environmental Suitability: Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Burial
-
Flammability / Reaction to Fire: UL 1685 UL Loading, FT4, T-29-520, IEEE 1202
-
NEC / UL Compliance: Article 725, Article 727, Article 800, CMG, ITC-ER, PLTC-ER
-
AWM Specification: AWM 2464
-
CEC / C(UL) Compliance: CMG
-
European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
-
APAC Compliance: China RoHS II (GB/T 26572-2011)
Construction
Conductors:
Belden wire may have different numbers of conductors that are drawn and annealed by the company and made of either solid or stranded copper.
Insulation:
Insulation is very important in any electrical cable since it prevents the electrocution of cable handlers. Belden cable’s insulation is made by the company, therefore offering a wide range of options, including Polyethylene, Polyvinyl Chloride (PVC), and Polypropylene insulation. Datalene and Teflon® Insulated Plenum insulation are also available.
Jacket:
The range of Belden wire jackets is quite wide and includes the following materials: Polyvinyl Chloride, Polyethylene, Polyurethane, Teflon®, Tefzel®, Neoprene, EPDM, Silicone rubber, and Natural rubber.
Shield:
Belden wire shields utilize techniques and innovations developed by the company and include the following variety: Foil shields (Beldfoil®, Duofoil®), Braid shields, Spiral/Serve shields, and Combination shields.
Armor:
Belden wire armor protects the cable and is made of aluminum or interlocking steel.
Details:
-
Max. Operating Temperature: 105°C
-
Max. Voltage Rating: 300V (PLTC-ER)
-
Conductor Material: Tinned Copper
-
Insulation Material: PVC
-
Jacket Material: PVC
-
Shield: Individual Beldfoil® (100% coverage)
Specifications:
-
Size (AWG): 18
-
Stranding: 19x30
-
Number of Conductors: 30
-
Number of Pairs: 15
-
Weight (lbs/1000ft): 368
-
Insulation Wall Thickness (inch): 0.016
-
Nominal O.D. (inch): 0.803
-
Nominal Capacitance (pF/ft): 61
*Data provided on this page is subject to change based on different manufacturers' variances