Belden 29513 10 AWG 3C 16 Single Pair XLPE 1000V Flexible Motor Supply Composite Cable
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
Belden 29513 10 AWG 3C 16 Single Pair XLPE 1000V Flexible Motor Supply Composite Cable
Applications:
The VFD cable is an electrical wire used in harsh environments, including high noise levels and voltage spikes, while supporting variable-frequency AC motor drives. The operating temperatures and voltage ratings of this electrical wire differ according to the product family.
Also Known As:
10 awg belden vfd cable, 10 awg shielded vfd cable.
Standards:
- Environmental Suitability: Indoor, Outdoor, Sunlight Resistance, Oil Resistance, Burial
- Sustainability: CA Prop 65
- Flammability / Fire Resistance: UL1685 UL Loading, FT4, FT4, 1202, 383 Vertical Tray Flame Test (70,000 BTU)
- NEC / UL Compliance: Article 336, TC-ER, XHHW-2, RHW-2, UL Flexible Motor Supply Cable
- AWM Compliance: I/II A/B
- CEC / C(UL) Compliance: CIC, TC
- ICEA Compliance: S-95-658
- European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
- APAC Compliance: China RoHS II (GB/T 26572-2011)
- Other Standard Compliance(s): P-07-KA070003-MSHA
Construction
Conductors:
Belden wire may have different numbers of conductors that are drawn and annealed by the company and made of either solid or stranded copper.
Insulation:
Insulation is very important in any electrical cable since it prevents the electrocution of cable handlers. Belden cable’s insulation is made by the company, therefore offering a wide range of options, including Polyethylene, Polyvinyl Chloride (PVC), and Polypropylene insulation. Datalene and Teflon® Insulated Plenum insulation is also available.
Jacket:
The range of Belden wire jackets is quite wide and includes the following materials: Polyvinyl Chloride, Polyethylene, Polyurethane, Teflon®, Tefzel®, Neoprene, EPDM, Silicone rubber, and Natural rubber.
Shield:
Belden wire shields utilize techniques and innovations developed by the company and include the following variety: Foil shields (Beldfoil®, Duofoil®), Braid shields, Spiral/Serve shields, and Combination shields.
Armor:
Belden wire armor protects the cable and is made of aluminum or interlocking steel.
Details:
- Max. Operating Temperature: -40°C to 90°C (dry/wet)
- Max. Voltage Rating: 1,000V RMS
- Conductor Material: Tinned Copper
- Insulation Material: XLPE/PVC
- Jacket Material: PVC
- Shield: Overall Beldfoil®+Tinned Copper Braid (85%)
Specifications:
- Conductor:
- Size (AWG): 10
- Number of Conductors: 3
- Stranding: 105x30
- Ground:
- Ground (AWG): 10
- Number of Ground: 1
- Stranding: 105x30
- Pair:
- Pair (AWG): 16
- Number of Pairs: 1
- Stranding: 26x30
- Weight (lbs/1000ft): 493.0
- Nominal Insulation Thickness (inch): 0.046
- Nominal Cable Diameter (inch): 0.985
- Nom. Imp. (Ω): 37
- Nominal Capacitance (pF/ft): 46.0
Manufacturer Equivalents |
|
Anixter : |
Black : 2ACD-1003+16-1PR-B |
Belden : | Black : 29513 0103000 |
Omni Cable : | Black : BEL29513 |
Wirexpress : | Black : 2ACD-1003+16-1PR-B |
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Reviews