700 MCM Aluminum RHH/RHW-2 XLP USE-2 Direct Burial Wire
nassaunationalcable.com/collections/aluminum-rhh-rhw-2-use-2-90-c-xlpe-insulation-600v/products/700-mcm-aluminum-rhh-rhw-2-xlp-use-2-direct-burial

Items in Cart ()

View cart

700 MCM Aluminum RHH/RHW-2 XLP USE-2 Direct Burial

700 MCM Aluminum RHH/RHW-2 XLP USE-2 Direct Burial
Roll over image to Zoom

700 MCM Aluminum RHH/RHW-2 XLP USE-2 Direct Burial

SKU: NNC4203X
aluminum-rhh-rhw-2-use-2-90-c-xlpe-insulation-600v
Min Length: 1 FT
Max Length: 10000 FT
Price:
Regular price
$0.00 /FT
Sale price
$0.00 /FT
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

700 MCM Aluminum RHH/RHW-2 XLP USE-2 Direct Burial

Allowable Ampacity for 700 MCM ALUMINUM RHH/RHW-2 XLP USE-2 DIRECT BURIAL: 480 Amps

Applications:

USE-2 cables are power distribution cables for service entrance below ground and direct burial, as well as raceways. The electrical cable is approved according to the National Electric Code, except for the use in cable trays. The maximum operating temperature for this electrical cable is 90°C in wet and dry locations. The voltage rating is 600 volts.

Also Known As:

700 mcm wire, 700 mcm aluminum wire, 700 mcm wire size, rhh wire, rhh cable, bury cable, direct burial electrical cable, direct burial mc cable.

Standards:

  • UL 44
  • UL 854
  • NEMA WC 70/ICEA S-95-658
  • Requirements of the National Electrical Code
  • ASTM B800, B801, B836
  • Sunlight resistant
  • Oil Resistant PRI/PRII
  • Gas and Oil Res GRI/GRII
  • RUS ACCEPTED

Construction

Conductors:

Compact bare 8000 series aluminum, with Class B stranding per ASTM. 

Insulation:

Abrasion, heat and moisture resistant cross-linked polyethylene insulation (XLP)

Specifications:

  • Gauge: 700

  • Stranding: 58

  • Conductor Diameter Inches: 1.059

  • Insulation Thickness Inches: 0.135

  • O.D. Inches: 1.147

  • New Weight lb/1000FT: 1039 lbs

  • Ampacity at 30°C: 480 Amps


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color

Download PDF Spec Sheet

Reviews

Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460