About :
Eaton Series G molded case circuit breaker, EG-frame, EG, Complete breaker, Fixed thermal, fixed magnetic trip, Single-pole, 20A, 600Y/347 Vac, 100 kAIC at 240 Vac, 65 kAIC at 480 Vac, 35 kAIC at 600Y/347 Vac, Bolt-on, 50/60 Hz.
Specifications :
Amps | 20 Amp |
---|---|
Breaker Interrupt Rating 1 | 200KA 120VAC |
Breaker Interrupt Rating 2 | 100KA 240VAC |
Breaker Interrupt Rating 3 | 65KA 277VAC |
Breaker Line Side Term Method | Busbar (No Lugs) |
Breaker Load Side Term Method | Lugs |
Category | Circuit Breakers |
Category Standards | IEC Rated;UL Listed;CSA Certified;CE Marked |
Circuit Breaker Type | Series G Molded Case Circuit Breaker |
Frame | EG-Frame |
Height | 1.5 |
In Stock | Yes |
Length | 6 |
Manufacturer | Eaton |
Maximum Interrupt Rating | 65KA 277VAC |
Number of Poles | 1 Pole |
Product Description | 347Volt, 20Amp, 1-Pole |
Trip Type | Thermal Magnetic |
UNSPSC | 39121616 |
UPC | 786685381695 |
Volts | 347V |
Width | 6.5 |
Features :
• Frame Type: EG (EG-Frame)
• The EG frame is a part of the Eaton series of molded case circuit breakers designed for general-purpose electrical distribution. EG breakers are known for their reliable performance in both standard and critical applications.
• Pole Configuration: 1 Pole
• This breaker is designed to protect a single phase circuit. It has one pole, meaning it can protect one live wire in an electrical system.
• Rated Current: 20 Amps
• The 20A rating (as indicated by "1020" in the part number) indicates that the breaker is designed to protect circuits carrying up to 20 amps of current. If the current exceeds this value, the breaker will trip to prevent damage to the circuit.
• Trip Type: Thermal Magnetic
• The breaker uses both thermal and magnetic trip mechanisms:
Thermal protection responds to overload conditions and will trip if the current exceeds the rated value over time.
Magnetic protection responds to short-circuit conditions with an instantaneous trip to prevent damage from high current surges.
• Voltage Rating:
• 240V AC or 480V AC (depending on the specific model variant) is typical for this type of breaker. It’s important to verify this based on your application.
Download PDF Spec Sheet
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460