COPPER SW STANDARD WALL XLPE LAMINATE SHEATH 345/400 kV XLPE POWER CABLE

Select a Gauge
Where are we? 4 Continents 9 Countries


Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
Product Name | Length | Price (Per FT.) | Action | |
---|---|---|---|---|
![]() |
Product Name
COPPER SW STANDARD WALL XLPE LAMINATE SHEATH 345/400 kV XLPE POWER CABLE |
Length
/FT
|
Price (Per FT.)
Call 516-482-6313 for pricing
|
Action
|
![]() |
Product Name
1250 MCM Copper SW Standard Wall Laminate Sheath 345/400 kV XLPE Power Cable |
Length
/FT
|
Price (Per FT.)
Call 516-482-6313 for pricing
|
Action
|
![]() |
Product Name
1500 MCM Copper SW Standard Wall Laminate Sheath 345/400 kV XLPE Power Cable |
Length
/FT
|
Price (Per FT.)
Call 516-482-6313 for pricing
|
Action
|
![]() |
Product Name
1750 MCM Copper SW Standard Wall Laminate Sheath 345/400 kV XLPE Power Cable |
Length
/FT
|
Price (Per FT.)
Call 516-482-6313 for pricing
|
Action
|
![]() |
Product Name
2000 MCM Copper SW Standard Wall Laminate Sheath 345/400 kV XLPE Power Cable |
Length
/FT
|
Price (Per FT.)
Call 516-482-6313 for pricing
|
Action
|
![]() |
Product Name
2500 MCM Copper SW Standard Wall Laminate Sheath 345/400 kV XLPE Power Cable |
Length
/FT
|
Price (Per FT.)
Call 516-482-6313 for pricing
|
Action
|
COPPER SW STANDARD WALL XLPE LAMINATE SHEATH 345/400 kV XLPE POWER CABLE
Applications:
Predominantly used for underground transmission in conduit systems, suitable for use in wet or dry locations, direct burial, underground duct, and where exposed to sunlight. To be used at 345,000 volts or less and at conductor temperatures not to exceed 90°C for normal operation.
Also Known As:
345/400 kV XLPE High Voltage Power Cable XLPE Insulated Copper Power Cable with Laminated Sheath 345 kV XLPE Cable – Copper Conductor, Laminated Sheath XLPE HV Power Cable – SW Type, Standard Wall 400 kV Laminated Sheath Copper XLPE Cable
Cable Construction:
Conductor: Concentric Stranded, Compact, or Segmental Copper Conductor
Conductor Shield: Smooth
Insulation: Super Clean XLPE Insulation with a true triple extrusion and dry curing process.
Shielding: Firmly Bonded Insulation Shield
Outer Sheath: Polyethylene jacket with an extruded semi-conductive outer layer.
Moisture Protection: Copper moisture-impervious sheath.
CABLE DATA:
Voltage Characteristics (kV)
Max Voltage Rating: 420
BIL Rating: 1300/1425
Temperatures (°C)
Nominal Conductor: 90
Max. Emergency Conductor: 105
Short Circuit Conductor: 250
Minimum Installation: -10
Design Characteristics
Design Standards: AEIC, IEC
Factory Test Voltages (@400 kV): 440 kV / 60 min.
XLPE Loss Factor: 0.0005
Relative Permittivity: 2.3
Standards & References:
• ICEA S-108-720 AEIC CS9 - And IEC 60840 or 62067 upon request as applicable
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460