3 1/2" Trade Electri Flexible Conduits Galvanized Steel Type LA Liquid
nassaunationalcable.com/es/products/3-1-2-trade-electri-flexible-conduits-galvanized-steel-type-la-liquidtight-jacket-pvc

Items in Cart ()

View cart

3 1/2" Trade Electri Flexible Conduits Galvanized Steel Type LA Liquidtight Jacket PVC

3 1/2" Trade Electri Flexible Conduits Galvanized Steel Type LA Liquidtight Jacket PVC
Roll over image to Zoom

3 1/2" Trade Electri Flexible Conduits Galvanized Steel Type LA Liquidtight Jacket PVC

SKU: 28505
electri-flexible-conduits-galvanized-steel-type-la-liquidtight-jacket-pvc
Price:
Precio habitual
$0.00 /Qty
Precio de oferta
$0.00 /Qty
Los gastos de envío se calculan en la pantalla de pagos.
Free Shipping: On orders above $1000
La cantidad debe ser 1 o más

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

No reviews yet
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

US Trade Size: 3 1/2"
ISO: 90 (mm)
CSA: 91 (mm)
Type: LA-350
Internal Diameter: Min: 3.500 Inches & Max: 3.540 Inches
Outer Diameter: Min: 3.960 Inches & Max: 4.000 Inches
Inside Bend Radius: Static: 11.0 Inches & Dynamic: 43.0 Inches
Weight: 323.4 Lbs
Reel 25ft: Part Gray: 28502
Reel 175ft: Part Gray: 28505


3 1/2" Trade Electri Flexible Conduits Galvanized Steel Type LA Liquidtight Jacket PVC

Allowable Ampacity for 3 1/2" Trade Electri Flexible Conduits Galvanized Steel Type LA Liquidtight Jacket PVC: 100 Amps

Application:

This conduit is intended for installation in accordance with Article 350 of the NEC (ANSI/NFPA-70) and in section 14.5.4 of the ANSI/NFPA-79 Standard for Industrial Machinery:

  • Listed and marked for Direct Burial and in Poured Concrete
  • For containment of 1000 volt and lower potential circuits
  • Suitable as a grounding conductor when used for circuits rated up to 20A for the 3/8 & 1/2 inch trade sizes and 60A for the 3/4 through 1-1/4 inch trade sizes in lengths six feet or less per NEC Article 250.118(6). Larger sizes require separate grounding conductor.
  • Installations in hazardous (classified) locations:
  • Class I Div. 2: Article 501.10 (B)(2) & 501.30 (B)
  • Class II Div. 1: Article 502.10 (A)(2) & 502.30 (B) Div. 2: 502.10 (B)(2)
  • Class III Div. 1: Article 503.10 (A)(3) & 503.30 (B) Div. 2: 503.10 (B)
  • Installed under raised floors in Data Processing Areas Articles 645.5 (E)
  • Electric Signs and Outline Lighting over 1000 volts Articles 600.7/600.32(A)(1)
  • Permitted for Service Entrance wiring to six feet Article 230.43
  • Used as Feeders and Services at Marinas and Boatyards Article 553.7(B)
  • Wiring on Building Article 225.10
  • Conductor Enclosures Adjacent to Motors over 1000 V Article 430.223
  • Underground Service, Feeder, Branch Circuit, and Recreational Vehicle Site Feeder Circuit Conductors Article 551.80
  • Elevators and Hoistways Article 620.21
  • Pools and Fountains Article 680
  • Bodies of water. Article 682
  • Fire Pumps. Article 695

This conduit is intended for use according to the Canadian Electrical Code (CEC CSA 22.1-18) as described in clause 12-1300 for dry, damp or wet locations.

  • Conforms to CSA C22.2 No. 56-17 Annex A “Heavy Duty”

Hazardous Locations areas where flexibility is necessary:

  • Class I Div 2: CSA 22.1 J18-152 (1) (i)
  • Class II Div 1: CSA 22.1 J18-204 (4) (b)
  • Class II Div 2: CSA 22.1 J18-254 (1) (h)
  • Class III Div 1: CSA 22.1 J18-304 (1) (f)
  • Class III Div 2: CSA 22.1 J18-354 (h)
  • Zone 2: CSA 22.1 18-152 (1) (h)
  • Zone 20: CSA 22.1 18-192 (3) (a)
  • Zone 21: CSA 22.1 18-202 (4) (a)
  • Zone 22: CSA 22.1 18-252 (1) (h)


Also Know As:

Electri Flexible Conduits, Flexible Conduits, Galvanized Steel, Liquidtight Jacket, Type LA Conduits, Jacketed Metallic, Flexible PVC, Flexible Steel Conduit, Heavy-Duty

Type LA

A exible steel conduitwhich is both listed by Underwriters Laboratories Inc. and certied by Canadian Standards Association for“Heavy-Duty” applications. It oers outstanding protection againstwet, oily conditions and is permitted for use in exposed or concealed locations.

Construction:

Inner Core:

  • Hot Dipped Galvanized Steel
  • 3/8” – 1-1/4” Squarelock Profile with continuous bonding strip
  • 1-1/2” – 4” Fully Interlocked Profile

Liquidtight Jacket:

  • Flexible PVC
  • Resistant to Oils and Mild Acids
  • Flame Retardant
  • Sunlight Resistant (UV)
  • Marked HD for “Heavy-Duty”

*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color

Reviews

Customer Reviews

No reviews yet
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460