Product Information
Specification
17 AWG 10P Stranded BC Shield Al Tape PE Armour PVC RE-2Y(St)YRY 300V Instrumentation CableAllowable Ampacity for 17 AWG 10P Stranded BC Shield Al Tape PE Armour PVC RE-2Y(St)YRY 300V Instrumentation Cable: 100 Amps
About:
This type of cable is typically used to transmit analog or digital signals in industrial settings. The construction of the cable ensures minimal interference from external electromagnetic sources, which is crucial for maintaining signal integrity in sensitive instrumentation applications.
Also Known As:
• Instrumentation Shielded Cable
• Armored PE Insulated Instrumentation Cable
• Aluminum Tape Shielded Instrumentation Cable
Application:
These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, natural gas and petroleum plants. With blue sheath it is suitable for intrinsically safe systems. these cables are for indoor/outdoor installation, in dry and wet locations, on rack trays, in conduits.
Standards:
• UL Standards for safety
• ANSI standards for instrumentation cables
• IEC standards for electrical and electronic equipment
Construction:
• Conductor: Stranded red copper conductor Cl. 2, acc. to IEC 60228, DIN VDE 0295
• Insulation: PE compound
• Colour cores: white-black, with black progressively numbered
• Stranding: Conductors twisted in pairs
• Wrapping: Polyester tape
• Screen: Electrostatic screen of plastic and aluminium tape + tinned drain-wire
• Inner Sheath: PVC compound
• Armour: Galvanized steel wires
• Outer Sheath: black (RAL 9005), or blue (RAL 5015), special PVC compound
Features:
• fl: On Request
• Standard TS/DIN EN 50288-7
• Insulation thickness: mm 0,50 0,75 1 1,3 1,5
mm 0,40 0,40 0,40 0,45 0,45
• Conductor Resistance: mm 0,50 0,75 1 1,3 1,5
Ohm/km 36,7 25 18,5 14,2 12,3
• Insulation Resistance: min. 5 GOhm x km
• Mutual Capacitance: ≤ 4 pairs all other pairs
0,50 mm2: max. 115 pF/m max. 90 pF/m
0,75 mm2: max. 115 pF/m max. 90 pF/m
1,0 mm2: max. 115 pF/m max. 90 pF/m
1,3 mm2: max. 120 pF/m max. 105 pF/m
1,5 mm2: max. 120 pF/m max. 105 pF/m
• Capacitance Unbalance: (1 kHz): max. 500 pF/500 m
• L/R (oran-ratio) (max.): mm² 0,50 0,75 1.0 1,3 1,5
mm² 25 25 25 40 40
Specifications:
• No. of pairs x cross section n x mm²: 10x2x1.3
• AWG no.: 17
• Outer-Ø ca.mm ± 10%: 23
• Copper Weight kg/km: 254
• Nominal Voltage: 300 V
• Test Voltage: 2 kV
• Temperature Range: - 30° C up to + 70° C
• Min. bending radius: 10 x d
• Cable Weight approx. kg/km: 925
• Part Number: 47140C.X102M13
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460