112-10-4122 4/0 AWG 3C 19 Stranded Bare Copper Shielded Okonite FMR Ok

Items in Cart ()

View cart

112-10-4122 4/0 AWG 3C 19 Stranded Bare Copper Shielded Okonite FMR Okolon TS-CPE UL TC CIC Tray Cable

112-10-4122 4/0 AWG 3C 19 Stranded Bare Copper Shielded Okonite FMR Okolon TS-CPE UL TC CIC Tray Cable
Roll over image to Zoom

112-10-4122 4/0 AWG 3C 19 Stranded Bare Copper Shielded Okonite FMR Okolon TS-CPE UL TC CIC Tray Cable

SKU: 112-10-4122

Select a Gauge

112-10-4122 4/0 AWG 3C 19 Stranded Bare Copper Shielded Okonite FMR Okolon TS-CPE UL TC CIC Tray Cable
Price:
Precio habitual
$0.00 /Qty
Precio de oferta
$0.00 /Qty
Los gastos de envío se calculan en la pantalla de pagos.
Free Shipping: On orders above $1000
La cantidad debe ser 1 o más

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

112-10-4122 4/0 AWG 3C 19 Stranded Bare Copper Shielded Okonite FMR Okolon TS-CPE UL TC CIC Tray Cable

Allowable Ampacity for 112-10-4122 4/0 AWG 3C 19 Stranded Bare Copper Shielded Okonite FMR Okolon TS-CPE UL TC CIC Tray Cable:100 Amps

About:

This cable is bare copper wires. It is shielded and designed for use in demanding environments where extended runs and exposure to harsh conditions are expected.

Also Known As:

 Okonite Tray Cable
 Okolon TS-CPE Cable

Application:

• Okonite-FMR Okolon TP-CPE tray cable is permitted for use on power, lighting, control, and signal circuits; indoors or outdoors; in cable trays, raceways, direct burial in the ground, or where supported in outdoor locations by a messenger wire; for Class 1 circuits as permitted by Article 725 of the NEC; and in cable trays in Class I Division 2 hazardous locations in industrial establishments where the conditions of maintenance and supervision assure that only qualified persons will service the installation.
• Cables marked TC-ER may also be used between a cable tray and the utilization equipment or device, when installed in accordance with NEC 336.10(7).
• Sizes  4/0 AWG are listed as c(UL) Type CIC and TC and are approved for installation in Zone 1, Zone 2, Class I Div. 2, Class II Div. 2, and Class III Div. 2 locations per the CEC.

Standards:

 NEC Type TC-ER (Tray Cable-Exposed Run) compliant, allowing for use in exposed runs without the need for conduit over specified distances
 UL listed for Direct Burial
 Passes IEEE 1202 flame test (FT4 Rating), ensuring fire resistance
 Meets CSA C22.2 No. 230 Tray Cable requirements
 Conforms to industry standards for oil and chemical resistance

Construction:

• Conductor: Uncoated soft copper per ASTM B-3. Sizes smaller than #8 are compress stranded per ASTM B-8. Sizes #8 and larger are compact stranded per ASTM B-496.
 Insulation: Okonite-FMR meets or exceeds requirements of UL 1581 and ICEA S-73 532 (NEMA WC57) & ICEA S-95-658 (NEMA WC70) Type II insulation.
• Color Coding: Base colors and tracers as shown on reverse of Data Sheet. For sizes #8 AWG and larger black conductors with surface printing of numbers per ICEA S-73- 532 NEMA/WC57 Method 4.
• Grounding Conductor: Where indicated, bare stranded copper per ASTM B-8 for sizes #7 AWG and smaller, compact round for sizes #8 AWG and larger per ASTM B-496 and in accordance with NEC Table 250.122.
• Assembly: Conductors cabled in accordance with UL 1277 using fillers, as necessary, with a cable tape overall.
• Overall Jacket: Complies with UL 1277. The Okolon TP-CPE compound meets or exceeds the requirements of UL 1581, ICEA S73-532 (NEMA WC57) & ICEA S-95-658 (NEMA WC70). UL Listed as Type TC or TC-ER cable with a sunlight resistant jacket and for direct burial. Sizes 4 AWG and larger, without a grounding conductor, are Type TC only (not ER).

Features:

 For cable tray use.
• For direct burial.
• Sunlight resistant.
• Insulated conductors are UL rated XHH/XHHW-2, cUL rated RW75/RW90, VW-1, PR I, and -40C.
• Flame Retardant - passes the vertical tray flame test requirements of IEEE 383-1974, IEEE 1202/FT4, UL 1277, and ICEA T-29-520 (210,000 BTU/hr.).
• UL listed for cable tray use.
• 90°C continuous rating in wet or dry locations 130°C emergency overload rating 250°C short circuit rating.
• Okonite-FMR Okolon TP-CPE cables are quality control inspected to meet or exceed applicable industry standards.
• Resistant to moisture and most chemical atmospheres.
• Thermal stability at elevated temperatures.
• Flexible, easy to install and terminate.
• Mechanically rugged.
• High dielectric strength.
• Small diameter, lightweight.
• Minimum installation temperature of -22°F or -30°C.
• CSA C22.2 No. 239 Type CIC for sizes 4/0 and smaller.
• CSA C22.2 No. 230 Type TC for sizes 4/0 and smaller.

Specifications:

• Conductor Size AWG/kcmil: 4/0(19X)
• UL TC Type: TC

 Number of Conductors:
3
• Insulation Thickness (miles): 55
• Grounding Conductor AWG:
• Jacket Thickness (miles): 80
• Jacket Thickness (mm): 2.03
• Approx. O.D (Inches):
1.48
• Approx. O.D (mm):
37.6
• Cross Sectional Area (sq. in):
• Approx. Net Weight: 2444
• 90°C Wet or Dry NEC Ampacity (1): 260
• 75°C Wet NEC Ampacity (1): 230
• Part Number: 112-10-4122


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color

Download PDF Spec Sheet

Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460