112-10-4072 2 AWG 3C 7 Stranded Bare Copper Shielded Okonite FMR Okolon TS-CPE UL TC CIC Tray Cable
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
112-10-4072 2 AWG 3C 7 Stranded Bare Copper Shielded Okonite FMR Okolon TS-CPE UL TC CIC Tray Cable
Allowable Ampacity for 112-10-4072 2 AWG 3C 7 Stranded Bare Copper Shielded Okonite FMR Okolon TS-CPE UL TC CIC Tray Cable:100 Amps
About:
This cable is bare copper wires. It is shielded and designed for use in demanding environments where extended runs and exposure to harsh conditions are expected.
Also Known As:
• Okonite Tray Cable
• Okolon TS-CPE Cable
Application:
• Okonite-FMR Okolon TP-CPE tray cable is permitted for use on power, lighting, control, and signal circuits; indoors or outdoors; in cable trays, raceways, direct burial in the ground, or where supported in outdoor locations by a messenger wire; for Class 1 circuits as permitted by Article 725 of the NEC; and in cable trays in Class I Division 2 hazardous locations in industrial establishments where the conditions of maintenance and supervision assure that only qualified persons will service the installation.
• Cables marked TC-ER may also be used between a cable tray and the utilization equipment or device, when installed in accordance with NEC 336.10(7).
• Sizes 4/0 AWG are listed as c(UL) Type CIC and TC and are approved for installation in Zone 1, Zone 2, Class I Div. 2, Class II Div. 2, and Class III Div. 2 locations per the CEC.
Standards:
• NEC Type TC-ER (Tray Cable-Exposed Run) compliant, allowing for use in exposed runs without the need for conduit over specified distances
• UL listed for Direct Burial
• Passes IEEE 1202 flame test (FT4 Rating), ensuring fire resistance
• Meets CSA C22.2 No. 230 Tray Cable requirements
• Conforms to industry standards for oil and chemical resistance
Construction:
• Conductor: Uncoated soft copper per ASTM B-3. Sizes smaller than #8 are compress stranded per ASTM B-8. Sizes #8 and larger are compact stranded per ASTM B-496.
• Insulation: Okonite-FMR meets or exceeds requirements of UL 1581 and ICEA S-73 532 (NEMA WC57) & ICEA S-95-658 (NEMA WC70) Type II insulation.
• Color Coding: Base colors and tracers as shown on reverse of Data Sheet. For sizes #8 AWG and larger black conductors with surface printing of numbers per ICEA S-73- 532 NEMA/WC57 Method 4.
• Grounding Conductor: Where indicated, bare stranded copper per ASTM B-8 for sizes #7 AWG and smaller, compact round for sizes #8 AWG and larger per ASTM B-496 and in accordance with NEC Table 250.122.
• Assembly: Conductors cabled in accordance with UL 1277 using fillers, as necessary, with a cable tape overall.
• Overall Jacket: Complies with UL 1277. The Okolon TP-CPE compound meets or exceeds the requirements of UL 1581, ICEA S73-532 (NEMA WC57) & ICEA S-95-658 (NEMA WC70). UL Listed as Type TC or TC-ER cable with a sunlight resistant jacket and for direct burial. Sizes 4 AWG and larger, without a grounding conductor, are Type TC only (not ER).
Features:
• For cable tray use.
• For direct burial.
• Sunlight resistant.
• Insulated conductors are UL rated XHH/XHHW-2, cUL rated RW75/RW90, VW-1, PR I, and -40C.
• Flame Retardant - passes the vertical tray flame test requirements of IEEE 383-1974, IEEE 1202/FT4, UL 1277, and ICEA T-29-520 (210,000 BTU/hr.).
• UL listed for cable tray use.
• 90°C continuous rating in wet or dry locations 130°C emergency overload rating 250°C short circuit rating.
• Okonite-FMR Okolon TP-CPE cables are quality control inspected to meet or exceed applicable industry standards.
• Resistant to moisture and most chemical atmospheres.
• Thermal stability at elevated temperatures.
• Flexible, easy to install and terminate.
• Mechanically rugged.
• High dielectric strength.
• Small diameter, lightweight.
• Minimum installation temperature of -22°F or -30°C.
• CSA C22.2 No. 239 Type CIC for sizes 4/0 and smaller.
• CSA C22.2 No. 230 Type TC for sizes 4/0 and smaller.
Specifications:
• Conductor Size AWG/kcmil: 2(7X)
• UL TC Type: TC
• Number of Conductors: 3
• Insulation Thickness (miles): 45
• Grounding Conductor AWG: —
• Jacket Thickness (miles): 80
• Jacket Thickness (mm): 2.03
• Approx. O.D (Inches): 0.99
• Approx. O.D (mm): 25.1
• Cross Sectional Area (sq. in): 0.77
• Approx. Net Weight: 872
• 90°C Wet or Dry NEC Ampacity (1): 130
• 75°C Wet NEC Ampacity (1): 115
• Part Number: 112-10-4072
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet