MV105 OR MV90 EPR Hypalon 133% Copper Cable 2.4kV 5kV
nassaunationalcable.com/es/products/single-conductor-non-shielded-epr-133-hypalon-cspe-jacket-mv-105-cable-5kv

Items in Cart ()

View cart

Single Conductor Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV

Single Conductor Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV
Roll over image to Zoom

Single Conductor Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV

SKU: NNC5118X

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

  Product Name Length Price (Per FT.) Action
8 AWG 1C Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV
Product Name

8 AWG 1C Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV

Length
/FT
Price (Per FT.)
Call 516-482-6313 for pricingOut Of Stock
Min: 1 FT
Max: 1000000 FT
Action

6 AWG 1C Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV
Product Name

6 AWG 1C Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV

Length
/FT
Price (Per FT.)
Call 516-482-6313 for pricingOut Of Stock
Min: 1 FT
Max: 1000000 FT
Action

4 AWG 1C Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV
Product Name

4 AWG 1C Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV

Length
/FT
Price (Per FT.)
Call 516-482-6313 for pricingOut Of Stock
Min: 1 FT
Max: 1000000 FT
Action

2 AWG 1C Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV
Product Name

2 AWG 1C Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV

Length
/FT
Price (Per FT.)
Call 516-482-6313 for pricingOut Of Stock
Min: 1 FT
Max: 1000000 FT
Action

1 AWG 1C Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV
Product Name

1 AWG 1C Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV

Length
/FT
Price (Per FT.)
Call 516-482-6313 for pricingOut Of Stock
Min: 1 FT
Max: 1000000 FT
Action

1/0 AWG 1C Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV
Product Name

1/0 AWG 1C Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV

Length
/FT
Price (Per FT.)
Call 516-482-6313 for pricingOut Of Stock
Min: 1 FT
Max: 1000000 FT
Action

2/0 AWG 1C Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV
Product Name

2/0 AWG 1C Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV

Length
/FT
Price (Per FT.)
Call 516-482-6313 for pricingOut Of Stock
Min: 1 FT
Max: 1000000 FT
Action

3/0 AWG 1C Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV
Product Name

3/0 AWG 1C Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV

Length
/FT
Price (Per FT.)
Call 516-482-6313 for pricingOut Of Stock
Min: 1 FT
Max: 1000000 FT
Action

4/0 AWG 1C Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV
Product Name

4/0 AWG 1C Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV

Length
/FT
Price (Per FT.)
Call 516-482-6313 for pricingOut Of Stock
Min: 1 FT
Max: 1000000 FT
Action

250 MCM 1C Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV
Product Name

250 MCM 1C Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV

Length
/FT
Price (Per FT.)
Call 516-482-6313 for pricingOut Of Stock
Min: 1 FT
Max: 1000000 FT
Action

350 MCM 1C Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV
Product Name

350 MCM 1C Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV

Length
/FT
Price (Per FT.)

$17.45

Available
Min: 1 FT
Max: 1000000 FT
Action

500 MCM 1C Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV
Product Name

500 MCM 1C Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV

Length
/FT
Price (Per FT.)
Call 516-482-6313 for pricingOut Of Stock
Min: 1 FT
Max: 1000000 FT
Action

750 MCM 1C Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV
Product Name

750 MCM 1C Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV

Length
/FT
Price (Per FT.)
Call 516-482-6313 for pricingOut Of Stock
Min: 1 FT
Max: 1000000 FT
Action

1000 MCM 1C Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV
Product Name

1000 MCM 1C Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV

Length
/FT
Price (Per FT.)
Call 516-482-6313 for pricingOut Of Stock
Min: 1 FT
Max: 1000000 FT
Action

Product Information

Specification

Single Conductor Non-Shielded EPR 133% Hypalon Jacket MV-105 Cable 5KV

Description:

A. Where NEC jurisdiction applies; as 5,000 volt nonshielded power cable. Type MV-105, for use at conductor temperatures not exceeding 105°C in wet or dry locations. Cables meet requirments of Article 310-6 of the National Electrical Code.

B. For other applications, as nonshielded power cables for use at 5000 volts 100% insulation level (grounded neutral) and 133% insulation level (ungrounded neutral) under the following conditions: (a) Single conductors mounted on insulation in free air in indoor or outdoor locations.

Circuit voltages are 2400 volts, 4160 volts and 4800 volts. (b) Random lay singles in metal conduit and nonmetallic conduit in dry locations at circuit voltage of 2400 volts, 4160 volts and 4800 volts, and in damp or wet locations at circuit voltages of 2400 volts and 4160 volts.

(c) Triplexed singles in metal conduit and nonmetallic conduit in damp or wet locations at circuit voltage of 4800 volts.

(d) Single conductors or triplexed singles in cable tray, spaced block supports or in messenger supported rings in dry, damp or wet locations at circuit voltages of 2400 volts and 4160 volts. 

(e) Triplexed singles in cable tray, spaced block supports or in messenger supported rings in damp or wet locations at circuit voltage of 4800 volts.

(f) Single conductors or triplexed singles, aerially, field-spun to grounded messenger in dry, damp or wet locations at circuit voltages of 2400 volts, 4160 volts, and 4800 volts.

Also Known As:

Hypalon Jacket Cable, MV Cable, Medium Voltage Cable, CSPE Cable, MV-105 Cable, MV 5K Cable.

Application: 

Listed by Underwriters Laboratories as 5,000 volt nonshielded cable, Type MV-105 per UL Standard 1072
Conforms to ICEA Pub. No. 539-693 and NEMA Pub. No. WC4 for Ethylene-propylene rubber-insulated Wire and Cable
• Sizes 1/0 and larger pass UL and IEEE Standard 383 ribbon burner flame test and are UL listed for CT use
• Construction: Annealed tinned copper conductor, extruded conductor shield, EPR insulation, discharge and moisture resistant Hypalon jacket, surface printed


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.

Download PDF Spec Sheet

Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460