Prysmian Airguard 250 MCM 3C MV105 8kV 3C EPR/PVC 100% Medium Voltage
nassaunationalcable.com/es/products/prysmian-airguard-250-mcm-3c-mv105-8kv-3c-epr-pvc-100-medium-voltage-power-cable

Items in Cart ()

View cart

Prysmian Airguard 250 MCM 3C MV105 8kV 3C EPR/PVC 100% Medium Voltage Power Cable

Prysmian Airguard 250 MCM 3C MV105 8kV 3C EPR/PVC 100% Medium Voltage Power Cable
Roll over image to Zoom

Prysmian Airguard 250 MCM 3C MV105 8kV 3C EPR/PVC 100% Medium Voltage Power Cable

SKU:
prysmian-airguard-mv105-8-kv-3c-epr-pvc-100-medium-voltage-power-cable
Min Length: 1 FT
Max Length: 10000 FT
Price:
Precio habitual
$0.00 /FT
Precio de oferta
$0.00 /FT
Los gastos de envío se calculan en la pantalla de pagos.
Free Shipping: On orders above $1000
La cantidad debe ser 1 o más

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

Prysmian Airguard 250 MCM 3C MV105 8kV 3C EPR/PVC 100% Medium Voltage Power Cable

Application:

• Prysmian’s patented AIRGUARD cable is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations) with 5X the impact performance and up to 3X the sidewall bearing pressure limit (at 3000 lbs per rad-ft) This enables longer pulls than with CCW type cables. Please call in regards to the product literature and performance testing and videos.
• Three conductor cable with stranded copper or aluminum conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric AIR BAG™layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric DRYLAM layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations.

Also Known As:

250 MCM Prysmian Airguard MV105, 250 MCM MV105 8KV cable, 250 MCM 3C EPR/PVC power cable, 250 MCM Medium voltage cable 8KV, 250 MCM Prysmian MV105 specs, 250 MCM Airguard medium voltage cable, 250 MCM EPR/PVC insulated cable, 250 MCM 100% MV105 8KV cable, 250 MCM MV105 8KV 3-conductor, 250 MCM Prysmian medium voltage power cable

Conductors:

Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.

Metallic Shield:

 Helically applied non-magnetic copper tape(s) over the insulation shield with a nominal overlap of 25%. A mylar ribbon is longitudinally applied under the copper tape shield for phase identification - 1C w/ Red, 1C w/ Blue, and 1C w/ Black.

Conductor Shield:

 Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.

Insulation:

Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.

Insulation Shield:

Extruded thermosetting semiconducting shield with controlled adhesion to
the insulation providing the required balance between electrical integrity and ease of stripping.

Grounding Conductors:

Bare stranded copper conductor per UL, ICEA, and ASTM.

Assembly:

Phase identified conductors cabled with fillers and grounding conductors, forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.

Mechanical Protection:

High strength and high crush resistant AIR BAG layer extruded over the core assembly.

Chemical Protection:

A layer of DRYLAM which consists of a 6mil longitudinally applied aluminum tape and a chemical resistant extruded polymer layer is applied.

Jacket:

Sunlight and moisture resistant polyvinyl chloride (PVC) jacket.

Standards:  

• UL 1072 ⁃ Type MV-105, For CT USE Direct Buried/Sunlight Resistant
• IEEE ⁃ Flame Retardant
• UL 1277 TC-ER⁃ Exposed Run Rating
• CSA⁃ CSA FT4 Flame Test CSA Cold Impact/Bend Test (-40C
• MSHA⁃ Type MP and Type MP-GC
• IEEE 1580⁃ Marine Shipboard Cable Rating
• ABS⁃ American Bureau of Shipping Type Approval

Specifications:

Size: 250 MCM
• Insulation Thickness (mils):
115
• No. of Ground Wires: 
3
Size of Ground Wires: 6 AWG
• Conductor Diameter (in):
0.522
• Insulation Diameter (in):
0.81
• Insulation Shield Diameter (in):
0.86
• Overall Jacket Diameter (in):
2.30
• Cable Weight:
4.974 lbs per ft
• Minimum Bending Radius (in):
17
• Ampacity (Amps): 105°C In Duct = 335, 105°C In Air/ Tray = 400
• Impedance (micro-ohms/ft):
Pos/Neg Seq = 57 + j34, Zero Seq = 704 + j18


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color

Download PDF Spec Sheet