About:
This cable features a stranded uncoated copper conductor, offering flexibility and robust electrical performance. The Okoguard insulation, known for its excellent electrical, thermal, and physical properties, is paired with a copper shield and an Okoclear-TS outer jacket. The MV-105 designation signifies that the cable is rated for medium voltage applications, specifically up to 5/8 kilovolts, and is designed to meet the rigorous demands of modern electrical infrastructure.
Also Known As:
• MV-105 Okoguard Cable
• 5/8kV Stranded Copper Power Cable
• Medium Voltage Okoclear-TS Insulated Cable
Applications:
• Okoguard shielded Okoclear-TS Type MV-105 power cables are recommended for use as
feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations, where a cable with low smoke/zero halogen characteristics is needed.
• Type MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to
sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 315.36 and 250.4(A)(5), or messenger supported in industrial establishments and electric utilities.
• May be installed in cable trays where permitted by NEC Section 315.32(3).
Standards:
• IEEE 1202 or UL 1685 for fire and smoke performance
• ICEA S-93-639/NEMA WC 74 for 5-35 kV power cables
• UL 1072 for medium voltage power cables
Construction:
• Conductor: Uncoated copper compact stranded per ASTM B-496.
• Strand Screen: Extruded semiconducting EPR strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, AEIC CS8, CSA C68.10, and UL 1072.
• Insulation: Meets or exceeds electrical and physical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, AEIC CS8, CSA C68.10, and UL 1072.
• Insulation Screen: Extruded semiconduction EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEAS-93-639/NEMA WC74 & S-97-682, AEIC CS8, CSA C68.10, and UL 1072.
• Shield: 5 mil bare copper tape helically applied, with 25% minimum overlap.
• Jacket: Meets or exceeds electrical and physical requirements of ICEA S-93-639
and CSA C68.10 for Type II crosslinked polyolefin jackets.
UL listed as Type MV-105, sunlight resistant and for use in cable tray in accordance with UL 1072.
CSA C68.10 listed as FT4-ST1, HALOGEN-FREE, SR, LTDD (-25C), and TC-ER.
Features:
• Low smoke/zero halogen jacket.
• Okoguard cables meet or exceed all recognized industry standards (UL,
NEMA/ICEA and IEEE).
• Triple tandem extruded, all EPR system.
• 105°C continuous operating temperature.
• 140°C emergency rating.
• 250°C short circuit rating
• Excellent corona resistance.
• Exceptional resistance to “treeing”.
• Screens are clean stripping.
• Exceptional resistance to moisture.
• Resistant to most oils, acids, and alkalis.
• UL listed: MV-105, Sunlight Resistant, Cable Tray Use, and Oil Res I & II.
• Passes the UL & IEEE 383-1974 and FT4/IEEE 1202 Vertical Tray Flame Test.