Igus MAT9630103 22 AWG 2P RJ45/Male M12 Connector PVC B&R iX67CA0E41.xxxx Powerlink Connection Cable
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
Igus MAT9630103 22 AWG 2P RJ45/Male M12 Connector PVC B&R iX67CA0E41.xxxx Powerlink Connection Cable
Allowable Ampacity for Igus MAT9630103 22 AWG 2P RJ45/Male M12 Connector PVC B&R iX67CA0E41.xxxx Powerlink Connection Cable: 100 Amps
Also Known as:
Connection Cable, Igus RJ45/Male Cable, IGUS Cable, Ready Cable, Base Cable, Powerlink Cable
Construction:
Conductor: Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (according to DIN EN 60228)
Conductor insulation: Mechanically high-quality TPE mixture (According to bus specification)
Conductor construction: According to bus specification
Conductor identification: According to bus specification.
Overall shield: Bending-resistant braiding made of tinned copper wires. Coverage approx. 55% linear, approx. 80% optical.
Outer jacket: Low adhesion, highly abrasion resistant mixture on the basis of PUR, adapted to suit the requirements in e-chains® (According to DIN EN 50363-10-2)
Jacket color: Yellow-green (similar to RAL 6018)
Properties and Approvals:
UV resistance: Medium
Oil resistance: Oil-resistant according to DIN EN 50363-10-2
Offshore: MUD-resistant following NEK 606 - status 2009
Silicone-free: Free from silicon which can affect paint adhesion (according to PV 3.10.7 – status 1992).
Halogen-free: Following EN 60754
UL/CSA AWM: see data sheet for details
NFPA 79: Following NFPA 79-2012 chapter 12.9
DNV: Certified according to DNV Type Testing – Certificate No.: 61 935-14 HH
Flame retardant: According to IEC 60332-1-2, CEI 20-35, VW-1, FT-1
EAC: Certified to no. TC RU C-DE. ME77.B.01218
CTP: Certified to no. C-DE.PB49.B.00416
Lead free: Following 2011/65/EU (RoHS-II)
CEI: Following CEI 20-35
Clean room: According to ISO Class 1. Outer jacket material complies with CF77.UL.05.12.D, tested by IPA according to standard 14644-1
DESINA: According to VDW, DESINA standardization
CE guideline: Following 2014/35/EU
Specification:
Number of Conductors and AWG size: 2PR x 22AWG (0.38)
Conductor: Bare Copper
Insulation: TPE
Jacket: PVC
Outer Diameter: 0.28 inch
Copper Index: 22.2 lbs/mft
Voltage: 50 V
Weight: 45.0 lbs/mft
Part Number: MAT9630103
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460