Applications:
- In free air and raceways in accordance with NEC
- Typical applications include audio, intercom, control, energy management and alarm circuits
- In ducts, cable trays or conduit
- In accordance with UL Subject 13 as PowerLimited Circuit Cable
- In Class 3 circuits in accordance with NEC Article 725
- In accordance with UL subject 2250 as Instrumentation Tray Cable (ITC)
- Permitted for use in Class I Division 2 industrial hazardous locations per NEC Article 501-4(b) for UL Type PLTC/ITC cables
- Per NEC Article 727 for Type PLTC/ITC
Features:
- Rated at 105˚C
- Good electrical properties
- Oil and sunlight resistance
- Flame-retardant
- Good mechanical properties
- Meets cold bend test at -25˚C
Also Known As:
Instrumentation Cable, Instrumentation Wire, Multiple Triad cables, Broadcasting, Assemble Equipment, or Mass Transit Systems.
Allowable Ampacity for General Cable 340060 16 AWG 16T Individual Shielded UL Type PLTC/ITC 300V Instrumentation Cable: 100 Amps
Construction:
Conductor:
- 20 AWG thru 16 AWG bare, annealed copper per ASTM B3
- Class B stranding per ASTM B8
Insulation:
- Polyvinyl Chloride (PVC)
- Color-coded: per ICEA Method 1; Triads - black, white and red. One conductor in each triad is printed alpha-numerically for easy identification
Shield:
Individual and overall shielded triads
- Individual triads are 100% shielded with Flexfoil® aluminum/polyester in contact with stranded tinned copper drain wire
- Overall shield is Flexfoil® aluminum/polyester in contact with stranded tinned copper drain wire
Jacket:
- Sunlight-resistant Polyvinyl Chloride (PVC)
Specifications:
-
AWG: 16
-
No. of Triads: 16
-
Stranding: 7/.0192
-
Insulation Type: PVC
-
Shielding: Overall shielded
-
Insulation Thickness: 0.015 in
-
Jacket Thickness: 0.070 in
-
Nominal Cable O.D.:1.075 in
-
Copper Weight LBS/ 1000 FT: 433 LBS
-
Net Weight LBS/ 1000 FT: 765 LBS
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
Video
pdf
Get in Touch
Live Chat
Get replies right away!
Email
info@nassaunationalcable.com
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460
Utiliza las flechas izquierda/derecha para navegar por la presentación o deslízate hacia la izquierda/derecha si usas un dispositivo móvil