4/2 NMD90 W/GRND Copper Building Wire 300V

Where are we? 4 Continents 9 Countries


Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
4/2 NMD90 W/GRND Copper Building Wire 300V
Applications:
Romex SIMpull NMD90 cables may be used for both exposed work in dry locations or concealed work in dry or damp locations. The maximum allowable conductor temperature is 90°C. The minimum recommended installation temperature is -25°C for two-conductor cables and -10°C for three-conductor cables (with suitable handling procedures). Material should be properly stored above 0°C for 24 hours prior to installation. The maximum voltage rating for all intended applications is 300 volts. Consult the Canadian Electrical Code for further information related to applications.
Also Known As:
4/2 AWG NMD90 copper wire, NMD90 4/2 building cable, 300V NMD90 wire with ground, NMD90 electrical house wiring, 4/2 AWG copper NMD90 300V, indoor building electrical cable, copper NMD90 4-2 wire specs, residential 4/2 AWG copper cable, grounded NMD90 4-2 wire.
Standards:
• ASTM B3 Soft or Annealed Copper Wire
• ASTM B8 Concentric-Lay-Stranded Copper Conductors
• CSA C22.2 No. 48 non-metallic sheathed cable
• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
• FT1 Flame Test (1,706 BTU/Hr nominal - Vertical Wire Flame Test)
Construction:
Conductor: Bare copper per ASTM B3. Sizes #14 AWG - #10 AWG are solid. Sizes #8 AWG - #2 AWG are Class B compressed stranded per ASTM B8
Insulation: All phases are insulated with Polyvinyl Chloride (PVC) with Nylon Sheath
Jacket: Polyvinyl Chloride (PVC) jacket utilizing SIMpull Technology.
Conductor Color Color Code:
• 2/C: Black, White
• 3/C: Black, White, Red
Jacket Color Color Code:
• White: General Residential Wiring
• Red: 2 Black and Red conductors - 208V-240V Circuits (no neutral)
• Orange: No. 10 AWG General Residential Wiring
• Yellow: No. 12 AWG General Residential Wiring
• Blue: No. 14 AWG - 2 black and white conductors - 120V Arc Fault Circuit Interupter Applications
Specifications:
• Size: 4 AWG
• Number of Conductors: 2
• Conductor Stranding: 7
• Diameter Over Cond. inch: 0.225
• Insulation Thickness: 50
• Jacket Thickness: 60
• Approx. OD inch: 0.839
• Copper Weight lb / 1000ft: 311
• Approx. Weight lb / 1000ft: 463
• DC Resistance @ 25°C Ω /1000ft: 0.258
• AC Resistance @ 75°C Ω /1000ft: 0.310
• Min Bending Radius inch: 3.300
• Allowable Ampacity 75°C: 85
• Allowable Ampacity 90°C: 95