350 MCM HVTECK Aluminum 175 mil NLEPR TS AIA 15kV 100% IL Red PVC Jacket CSA

Where are we? 4 Continents 9 Countries


Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
350 MCM HVTECK Aluminum 175 mil NLEPR TS AIA 15kV 100% IL Red PVC Jacket CSA
Application:
The 15kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs /FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.
Also Known As:
350 MCM HVTECK 15kV cable, HVTECK aluminum 3 conductor, HVTECK 175 mil NLEPR, HVTECK TS AIA cable, 350 MCM HVTECK 15kV 100% insulation level, HVTECK red PVC jacket CSA, HVTECK 3/C aluminum 15kV, 350 MCM HVTECK AIA armored cable, HVTECK 15kV CSA certified, 350 MCM HVTECK 3 conductor NLEPR PVC.
Standards:
• ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy
• ASTM B836 Compact Rounded Stranded Aluminum Conductors
• CSA C22.2 No. 174 Cables in Hazardous Locations
• CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods
• CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
• CSA C68.3 Shielded & Concentric Neutral Power Cable - 5 to 46 kV
• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating
• CSA HL - for Hazardous Locations rating
• CSA SUN RES - for Sunlight Resistant rating
• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
• ICEA T-29-520 Flame Test (210,000 BTU/Hr)
• IEEE 383 Flame Test (70,000 btu)
• IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
• FT1 Flame Test (1,706 BTU/Hr nominal - Vertical Wire Flame Test)
• AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
Construction:
• Conductor: Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836
• Conductor Shield: Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or
equal to 500 Kcmil
• Insulation: 175 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 100% insulation level
• Insulation Shield: Strippable semi-conducting cross-linked copolymer
• Copper Tape Shield: Helically wrapped 5 mil copper tape with 25% overlap
• Filler: Interstices filled with non-hydroscoping/non-wicking fillers
• Grounding Conductor: Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8
• Binder: Polypropylene tape
• Inner Jacket: PVC inner jacket
• Armour: Aluminum Interlocked Armour (AIA)
• Overall Jacket: Red Polyvinyl Chloride (PVC) Jacket
Specifications:
• Size: 350 MCM
• Number of Strands: 37
• Diameter Over Conductor (inch): 0.615
• Diameter Over Insulation (inch): 1.011
• Insul. Thickness mil: 175
• Diameter Over Insulation Shield (inch): 1.071
• Ground No. x AWG: 4
• Inner Jacket Thickness (mil): 110
• Diameter Over Armor (inch): 2.933
• Overall Jacket Thickness mil : 75
• Approx. OD inch : 3.083
• Approx. Weight (Lbs/1000'Ft): 3944
• Min Bending Radius (In): 21.6
• DC Resistance @ 25°C Ω /1000ft: 0.050
• AC Resistance @ 90°Ω /1000ft: 0.065
• Inductive Reactance @ 60HzΩ/1000ft: 0.030
• Allowable Ampacity In Air 90°C Amp: 363
• Allowable Ampacity Directly Buried 90°C Amp: 386
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460