350 MCM 3C W/GRND TECK 90 Copper Unshielded EPR Power Cable Orange PVC Jacket 5kV
Application:
Southwire’s 5KV TECK 90, 5000V, non-shielded, EPR insulated power cable is a CSA approved armoured cable for industrial and commercial medium voltage applications. FT4, -40°C, HL, AG14 and 90°C rated for use in harsh Canadian environments. Rated for installation in cable trays, duct banks, direct burial, troughs, hazardous locations, continuous rigid cable supports, and is concrete encaseable.
Also Known As:
350 MCM TECK90 5kV Copper Cable, 350 MCM TECK90 5kV Armored Power Cable,5kV TECK90 Non-Shielded EPR Power Cable, 350 MCM CSA TECK 90 Armored Cable, 350 MCM TECK90 5kV Orange PVC Jacket Cable, 350 MCM 5kV TECK90 EPR Insulated Cable.
Standards:
• ASTM B3 Soft or Annealed Copper Wire
• ASTM B8 Concentric-Lay-Stranded Copper Conductors
• CSA C22.2 No. 174 Cables in Hazardous Locations
• CSA C22.2 No. 131 Type TECK 90 Cable
• CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods
• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating
• CSA HL - for Hazardous Locations rating
• CSA SUN RES - for Sunlight Resistant rating
• CSA AG14 - Acid Gas Compliance
• ICEA S-96-659 (NEMA WC 71) 2001-5000 V Nonshielded Cables
• IEEE 383 Flame Test (70,000 btu)
• IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
• FT1 Flame Test (1,706 BTU/Hr nominal - Vertical Wire Flame Test)
Construction:
• Conductor: Class B stranded copper, compressed or compact, in accordance with ASTM B3 and B8.
• Conductor Shield: Extruded semi-conducting thermosetting polymeric layer
• Insulation: No-Lead EPR (ethylene propylene rubber), Thickness: 0.090” (2.3 mm) - nominal, 90°C
• Grounding Conductor: Class B compressed or compact stranded bare copper, in accordance with ASTM B3 and B8
• Binder: Polypropylene tape
• Inner Jacket: Black PVC, Thickness: No. 2 AWG to No. 3/0 AWG = 0.080” (2.0 mm); No. 4/0 AWG to 500 kcmil = 0.110” (2.8 mm); 750 kcmil to 1000 kcmil = 0.140” (3.6 mm)
• Armor: Aluminum Interlocked Armour (AIA)
• Overall Jacket: Orange PVC (optional colours available), Thickness: No. 2 AWG to 250 kcmil = 0.060” (1.5 mm); 350 kcmil to 750 kcmil = 0.075” (1.9 mm); 1000 kcmil = 0.090” (2.3 mm)
Specifications:
• Size: 350 MCM
• Conductor Number: 3
• Number of Strands: 37
• Diameter Over Conductor (inch): 0.661
• Insulation Thickness (Mil): 90
• Ground No. x AWG: 1x3
• Inner Jacket Thickness (mil): 115
• Diameter Over Armor (inch): 2.505
• Overall Jacket Thickness (mil): 65
• Approx. OD (In): 2.637
• Approx. Weight (Lbs/1000'Ft): 5196
• Min Bending Radius (In): 18.4
• Max Pull Tension lb: 8400
• Allowable Ampacity In Air 90°C (Amp): 460
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460