350 MCM 1C Stranded Tinned Copper Shielded Braid Halogen-Free GAALSHIP
nassaunationalcable.com/es/products/350-mcm-1c-stranded-tinned-copper-shielded-braid-halogen-free-gaalship-rfou-6-10kv-offshore-cable

Items in Cart ()

View cart

350 MCM 1C Stranded Tinned Copper Shielded Braid Halogen-Free GAALSHIP RFOU 6/10KV Offshore Cable

350 MCM 1C Stranded Tinned Copper Shielded Braid Halogen-Free GAALSHIP RFOU 6/10KV Offshore Cable
Roll over image to Zoom

350 MCM 1C Stranded Tinned Copper Shielded Braid Halogen-Free GAALSHIP RFOU 6/10KV Offshore Cable

SKU: 16020QRL010M70
gaalship-rfou-stranded-tinned-copper-shielded-braid-halogen-free-offshore-cable

Select a Gauge

350 MCM 1C Stranded Tinned Copper Shielded Braid Halogen-Free GAALSHIP RFOU 6/10KV Offshore Cable
Price:
Precio habitual
$0.00 /Qty
Precio de oferta
$0.00 /Qty
Los gastos de envío se calculan en la pantalla de pagos.
Free Shipping: On orders above $1000
La cantidad debe ser 1 o más

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

350 MCM 1C Stranded Tinned Copper Shielded Braid Halogen-Free GAALSHIP RFOU 6/10KV Offshore Cable

Allowable Ampacity for 350 MCM 1C Stranded Tinned Copper Shielded Braid Halogen-Free GAALSHIP RFOU 6/10KV Offshore Cable: 100 Amps

About:

This cable is engineered for high voltage power distribution in offshore oil drilling platforms, ships, and similar marine applications. Its halogen-free construction significantly reduces the emission of toxic gases and smoke in the event of a fire, enhancing safety.

Also Known As:

This type of cable may be referred to by various names in different markets, often highlighting its high voltage rating (6/10 kV) and halogen-free properties, or it might be recognized for its specific application or construction features in offshore and marine environments.

Application:

 High voltage power transmission in offshore drilling rigs
 Power supply for critical systems on marine vessels that require robust fire safety
 Fixed installations on ships where high voltage and fire resistance are essential

Standards:

 NEK 606: Which covers offshore and shipboard non-drilling cable specifications
 IEC 60092 Series: Focusing on electrical installations in ships, particularly in terms of safety and performance
 IEC 60332-3-22: Ensuring flame retardant and fire-resistant properties

Construction:

• Conductor: Stranded tinned copper conductor Cl. 2, acc. to IEC 60228
 Insulation: EPR, halogen-free compound acc. to IEC 60092-351,thickness acc. to IEC 60092-353
 Wrapping: Semiconducting tape and/or semiconducting layer.
 Screen: Semiconducting layer and tinned copper wire braid.
 Colour Cores: 1x: natural color 3x: white-black-red
 Inner Sheath: Halogen-free compound acc. to IEC 60092-354
 Armouring: Tinned copper wires braid acc. to IEC 60092-350, IEC 60092-352 used as earth conductor
 Outer Sheath: red (RAL 3000), halogen-free mud resistant thermosetting type SHF MUD, acc. to NEK IIII ed. 2009. Thickness acc. To IEC 60092-354

Features:

 Sheathing materials acc. to: IEC 60092-359
 Insulating materials acc. to: IEC 60092-351
 Design guidelines acc. to: IEC 60092-350-353 / …-350 NEK 606 IIII ed. 2009
 Choice and installation of electric cables acc. to: IEC 60092-352
 On request class 5
 On request halogen free thermosetting type SHF2 outer sheath, acc. to IEC 60092-359 and CSA 22.2 n.38-95 cold bend-impact test at low temperature (-40°C)
 acc. to NEK 606 IIII ed. 2009, Halogen free & MUD resistance cables, for the marine, ship and offshore
We have possibility to provide the following Certifications
on request:
 Det Norske Veritas (DNV)
 Lloyd’s Register (LR)

Specifications:

• No. of cores x cross section n x mm²: 1x185
• AWG no.: 350 MCM
• Ø under armour ca.mm ± 10%: 32
• Outer-Ø ca.mm ± 10%: 37,8
• Nominal Voltage: Uo/U 3,6/6 kV, Uo/U 6/10 kV, Uo/U 8,7/15 kV, Uo/U 12/20 kV
• Test Voltage: Uo/U 3,6/6 kV = 11 kV, Uo/U 6/10 kV = 17 kV, Uo/U 8,7/15 kV = 24 kV, Uo/U 12/20 kV = 29 kV
• Max. operating Voltage: Uo/U 3,6/6 kV = Um 7,2 kV, Uo/U 6/10 kV = Um 12 kV, Uo/U 8,7/15 kV = Um 17,5 kV, Uo/U 12/20 kV = Um 24 kV

• Temperature Range: - 40°C up to +90°C, Installation temp.: - 20 °C
• Short circuit temperature: +250°C
• Min. bending radius: 9 x D
• Cable Weight approx. kg/km: 3235
• Part Number: 16020QRL010M70 


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color

Download PDF Spec Sheet

Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460