2 AWG 3C HVTECK Copper 140 mil NLEPR TS AIA 8kV 133% IL Orange PVC Jacket CSA

2 AWG 3C HVTECK Copper 140 mil NLEPR TS AIA 8kV 133% IL Orange PVC Jacket CSA
Roll over image to Zoom
2 AWG 3C HVTECK Copper 140 mil NLEPR TS AIA 8kV 133% IL Orange PVC Jacket CSA
SKU: NNC16550
hvteck-copper-3-c-140-mil-nlepr-ts-aia-8kv-133-il-pvc-jacket-csa
Min Length: 1 FT
Max Length: 10000 FT
Price:
Precio habitual
$0.00 /FT
Precio de oferta
$0.00 /FT
Los gastos de envío se calculan en la pantalla de pagos.
Free Shipping: On orders above $1000
La cantidad debe ser 1 o más

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 9 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Product Information
Specification

2 AWG 3C HVTECK Copper 140 mil NLEPR TS AIA 8kV 133% IL Orange PVC Jacket CSA

Application:

The 8kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs /FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.

Also Known As:

2 AWG 3C HVTECK 8kV Copper 3 Conductor Cable, 3/C 140 mil NLEPR Power Cable, 8kV 133% Insulation Copper Cable, CSA Certified 8kV Copper Cable, 8kV TS AIA Armored Copper Cable, 140 mil NLEPR Insulated Cable, 2 AWG 3C HVTECK Copper 3/C 8kV CSA Cable, 8kV Copper Medium Voltage Cable, PVC Jacketed 8kV Copper Cable, 2 AWG 3C Triple Conductor 8kV HVTECK Cable.

Construction:

• Conductor: Class B compressed stranded bare copper per ASTM B3 and ASTM B8
• Conductor Shield: 
Semi-conducting cross-linked copolymer
• Insulation: 
140 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level
•  Insulation Shield: 
Strippable semi-conducting cross-linked copolymer
• Copper Tape Shield: 
Helically wrapped 5 mil copper tape with 25% overlap
•  Filler: 
Interstices filled with non-hydroscoping/non-wicking fillers
• Grounding Conductor: 
Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8
• Binder: 
Polypropylene tape
• Inner Jacket: 
PVC inner jacket
•  Armour: 
Aluminum Interlocked Armour (AIA)
•  Overall Jacket: 
Orange Polyvinyl Chloride (PVC) Jacket

Standards:

• ASTM B3 Soft or Annealed Copper Wire
• ASTM B8 Concentric-Lay-Stranded Copper Conductors
• CSA C22.2 No. 174 Cables in Hazardous Locations
• CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods
• CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
• CSA C68.3 Shielded & Concentric Neutral Power Cable - 5 to 46 kV
• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating
• CSA HL - for Hazardous Locations rating
• CSA SUN RES - for Sunlight Resistant rating
• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
• ICEA T-29-520 Flame Test (210,000 BTU/Hr)
• IEEE 383 Flame Test (70,000 btu)
• IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test (1/0 and Larger)
• IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
• FT1 Flame Test (1,706 BTU/Hr nominal - Vertical Wire Flame Test)
• AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)

Specifications:

• Size: 2 AWG
• Number of Strands:   7
• Diameter Over Conductor (inch):  0.282
• Diameter Over Insulation (inch):  0.600
• Insul. Thickness mil: 140
• Diameter Over Insulation Shield (inch):  0.660
• Ground Size AWG:  6

• Inner Jacket Thickness (mil): 80
• Diameter Over Armor (inch):  1.985
• Overall Jacket Thickness mil :  60
• Approx. OD inch : 2.105
• Copper Weight lb/1000ft: 741
• Approx. Weight (Lbs/1000'Ft): 2181
• Min Bending Radius (In):  14.7
• DC Resistance @ 25°C Ω /1000ft:   0.162
• AC Resistance @ 90°Ω /1000ft:   0.204
• Inductive Reactance @ 60HzΩ/1000ft:  0.042
• Allowable Ampacity In Air 90°C Amp:  172
• Allowable Ampacity Directly Buried 90°C Amp:  201


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet

 

Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460

Win an Exclusive prize!

Enter your full name and email to spin the wheel for a chance to win

Powered by CareCart