19 AWG 16T Stranded TC Shield Polyester Tape Halogen-Free GAALSHIP RU(
nassaunationalcable.com/es/products/19-awg-16t-stranded-tc-shield-polyester-tape-halogen-free-gaalship-ruc-offshore-cable

Items in Cart ()

View cart

19 AWG 16T Stranded TC Shield Polyester Tape Halogen-Free GAALSHIP RU(c) Offshore Cable

19 AWG 16T Stranded TC Shield Polyester Tape Halogen-Free GAALSHIP RU(c) Offshore Cable
Roll over image to Zoom

19 AWG 16T Stranded TC Shield Polyester Tape Halogen-Free GAALSHIP RU(c) Offshore Cable

SKU: 14060C5X163M07
gaalship-ruc-stranded-tc-shield-polyester-tape-halogen-free-offshore-cable

Select a Gauge

19 AWG 16T Stranded TC Shield Polyester Tape Halogen-Free GAALSHIP RU(c) Offshore Cable
Price:
Precio habitual
$0.00 /Qty
Precio de oferta
$0.00 /Qty
Los gastos de envío se calculan en la pantalla de pagos.
Free Shipping: On orders above $1000
La cantidad debe ser 1 o más

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

19 AWG 16T Stranded TC Shield Polyester Tape Halogen-Free GAALSHIP RU(c) Offshore Cable

Allowable Ampacity for 19 AWG 16T Stranded TC Shield Polyester Tape Halogen-Free GAALSHIP RU(c) Offshore Cable:100 Amps

About:

The 19 AWG 16T Stranded TC Shield Polyester Tape Halogen-Free GAALSHIP RU(c) Offshore Cable is a durable and reliable cable designed for offshore applications. With halogen-free insulation, it offers increased safety by reducing the risk of toxic gas emission in case of fire. This cable is ideal for harsh marine environments, providing robust electrical connectivity while meeting industry standards for performance and environmental compliance.

Also Known As:

19 AWG TC Shield Cable
 Halogen-Free Marine Cable
 Polyester Tape Shield Cable

Application:

• Offshore Installations: Ideal for use in offshore oil rigs, platforms, wind farms, and other marine environments where robust and reliable cables are required.
• Instrumentation and Control:
Suitable for transmitting signals and power in instrumentation, control, and communication systems on offshore facilities.
• Harsh Environments:
Designed to withstand exposure to moisture, saltwater, corrosive elements, and extreme temperatures encountered in offshore operations.

Standards:

Likely meets relevant industry standards and regulations for offshore cables, ensuring compliance with performance, safety, and environmental requirements.
May have certifications from recognized authorities or organizations validating its suitability for offshore applications.

Construction:

• Conductor: stranded tinned copper conductor Cl. 2, acc. to IEC 60228
• Insulation: 
EPR, halogen-free compound acc.to IEC 60092-351, thickness acc. to IEC 60092-376
• Cores color: 
pair: black- light blue triple: black- light blue - brown
• Stranding: 
cores lay-up in pairs, triples, laying-up of pairs, triples
• Screen: 
overall screen, copper/polyester tape with tinned copper stranded drain wire and synthetic tape
• Outer sheath: 
grey (RAL 7001), halogen-free mud resistant thermosetting type SHF MUD, acc. to NEK IIII edit. 2009. thickness acc. to IEC 60092-376

Features:

 Sheathing materials acc. to: IEC 60092-359
 Insulating materials acc. to: IEC 60092-351
 Design guidelines acc. to: IEC 60092-350-376 / …-350 NEK 606 IIII ed. 2009
 Choice and installation of electric cables acc. to: IEC 60092-352
 on request class 5
 on request halogen free thermosetting type SHF2 outer sheath,  acc. to IEC 60092-359 and CSA 22.2 n.38-95 cold bend-impact test at low temperature (-40°C)
 acc. to NEK 606 IIII ed. 2009, Halogen free & MUD resistance cables, for the marine, ship and offshore
We have possibility to provide the following Certifications
on request:
 Det Norske Veritas (DNV)
 Lloyd’s Register (LR)

Specifications:

• AWG No: 19
• No.of pairs/triples x cross section n x mm2:
16x3x0,75

• Outer-Øca.mm ± 10%: 23,1
• Copper weight kg/km: 329

• Nominal voltage: Uo/U 150/250 V
• Temperature range:  - 40°C up to +90°C
 Installation temp: - 20 °C
 Short circuit temperature: +250°C
• Min. bending radius: 8 x D
• Cable weight approx. kg/km: 845
• Part Number: 14060C5X163M07


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color

Download PDF Spec Sheet

Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460