18 AWG 24P PLTC Instrumentation Tray Cable Individual and Overall Shield PVC/CPE 300V
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
18 AWG 24P PLTC Instrumentation Tray Cable Individual and Overall Shield PVC/CPE 300V
Application:
• The cables can be used in raceways or, when provided with a messenger, for aerial application. When increased mechanical, chemical, or environmental protection is required, a hermetically sealed aluminum tape or copper tape armor with an additional PCV or CPE jacket can be provided.
• Cable is suitable for use in Class I Division II hazardous locations.
• Cable is UL approved for Sunlight Resistant and Direct Burial Applications.
• Recommended Operating Voltage: 300V
Scope:
• These Instrumentation Cables are UL listed under Article 725 of the NEC and are suitable for cable tray use in Class 1, Division 2 hazardous locations. The cable can be used in wet or dry locations and up to conductor temperatures of 105°C.
• The individually shielded pairs and triads are completely isolated from each other by use of a polyester tape. This shielding assures maximum protection from crosstalk and common mode interference. An overall shield provides additional protection.
• The flame properties meet or exceed the requirements of both the UL 70,000 BTU vertical tray flame test and the comparable IEEE-383 flame test. A 210,000 BTU rating is also available upon request.
Also Known As:
18 AWG 24P PLTC Cable, Instrumentation Cable, 18 AWG 24P 300V PLTC Tray Cable, 18 AWG 24P PVC/CPE 300V Instrumentation Tray Cable, PVC/CPE Instrument Cable, PLTC Tray Cable, 18/24P PVC/CPE 300V Individual and Overall Shield Instrumentation Tray, PVC/CPE Cable.
Construction:
Class B, stranded per ASTM B-3 and ASTM B-8
Primary Insulation:
105°C rated PVC
Thickness: .015" nominal thickness
Shielding:
Each pair with individual drain wire is shielded with aluminum /polyester tape. All are isolated with an additional polyester tape. Overall shield is helically applied with 100% coverage with a tinned copper drain wire.
Overall Jacket:
PVC (105°C rated) or CPE (90°C rated).
Ripcord is applied under the jacket to facilitate stripping.
Standards:
UL listed as type PLTC & CL3 per UL standard 13 as type ITC per UL standard 2250.
Meets IEEE 1202 flame test.
All materials used in the manufacture of this cable are RoHS compliant.
Specifications:
• AWG: 18
• No. of Pairs: 24
• Nominal Jacket Thickness (In): .072
• Nominal Outside Diameter (In): 1.038
• Pulling Tension (Pounds): 830
• Nominal Weight 1000 FT (Pounds): 614
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460