163-23-3090 350 MCM 1C Stranded Aluminum Unshielded EPR Concentric BC

Items in Cart ()

View cart

163-23-3090 350 MCM 1C Stranded Aluminum Unshielded EPR Concentric BC Full Neutral 220mils 15KV Okoguard URO-J Cable

163-23-3090 350 MCM 1C Stranded Aluminum Unshielded EPR Concentric BC Full Neutral 220mils 15KV Okoguard URO-J Cable
Roll over image to Zoom

163-23-3090 350 MCM 1C Stranded Aluminum Unshielded EPR Concentric BC Full Neutral 220mils 15KV Okoguard URO-J Cable

SKU: 163-23-3090

Select a Gauge

163-23-3090 350 MCM 1C Stranded Aluminum Unshielded EPR Concentric BC Full Neutral 220mils 15KV Okoguard URO-J Cable
Price:
Precio habitual
$0.00 /Qty
Precio de oferta
$0.00 /Qty
Los gastos de envío se calculan en la pantalla de pagos.
Free Shipping: On orders above $1000
La cantidad debe ser 1 o más

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

163-23-3090 350 MCM 1C Stranded Aluminum Unshielded EPR Concentric BC Full Neutral 220mils 15KV Okoguard URO-J Cable

Allowable Ampacity for 163-23-3090 350 MCM 1C Stranded Aluminum Unshielded EPR Concentric BC Full Neutral 220mils 15KV Okoguard URO-J Cable:100 Amps

About:

This cable is designed for 15KV applications and features a 350 MCM AWG stranded aluminum conductor with ethylene propylene rubber (EPR) insulation. The concentric bare copper (BC) full neutral enhances grounding and safety, making it ideal for robust underground residential distribution (URO) networks.

Also Known As:

350 MCM AWG 15KV Stranded Aluminum URO-J Cable
 Full Neutral Medium Voltage URO-J Cable
 Stranded Aluminum EPR Insulated URO Cable

Application:

 Okoguard URO-J cables provide maximum circuit longevity in underground residential distribution systems. They can be buried directly or installed in underground ducts or conduits.

Standards:

 Adheres to IEEE standards for medium voltage power cables.
 Complies with ANSI specifications for underground residential cables.
 Meets safety and environmental standards, including resistance to flame, moisture, and chemicals.

Construction:

• Central Conductor: Aluminum per ASTM B-609, Class B stranded per B-231.
• Filled Strand: Water swellable agent meets or exceeds ICEA T-31-610 water penetration resistance and ANSI/NEMA class A connector ability requirements.

• Conductor Screen:
 Extruded semiconucting ethylene-propylene rubber meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.
 Insulation: Extruded Okoguard meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and C68.5.
• Insulation Screen:
 Extruded semiconducting ethylene-propylene rubber meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.
• Concentric Conductor: 
Bare copper wire
 Jacket: Black Okolene with red extruded stripes meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5 for polyethylene jackets.

Features:

 Triple tandem extruded, all EPR system.
 Okoguard cables meet or exceed ICEA standards.
 Meets RUS 1728.204 for cables with filled strand or solid conductor and 133% insulation level.
 105°C continuous operating temperature.
 140°C emergency rating.
 250°C short circuit rating. • Excellent corona resistance.
 Low dielectric constant and power factor.
 Screens are clean stripping.
 Exceptional resistance to "treeing".
 Filled strand conductor.
 Moisture resistant.
 Overall jacket provides extended life.
 Excellent resistance to most chemicals.
 Can be listed by UL as Type MV-90 on Special Orders.
 CSA C68.5 listed, LTGG (-40°C), SR.
 Design Options: Additional conductor sizes Copper central conductor Copper flat strap concentric neutral Product identification via colored jackets. Semiconducting jackets.
 Improved Temperature Rating. Okoguard insulation system has been tested and qualified for operation at 105°C continuous and 140°C emergency operating temperature.
 Minimum installation temperature of 1/0 AWG OKOGUARD EPR 100% INSUL -40°C.

Specifications:

• Conductor Size AWG kcmil: 350(37X)
• Nominal Dia. Over Insulation (in): 1.16

• Insulation Screen Thickness (miles):
 40 
• Nominal Dia. Over Insulation Screen (in): 1.26
• Copper Neutral, No. x AWG(1): 18X.1078
• Nominal O.D (In): 1.59
• Approx. Net Weight: 1721
• 90° C Ampacity Direct Burial (2): 425

• 90° C Ampacity Duct (2): 310
• 105° C Ampacity Direct Burial (2): 460
• 105° C Ampacity Duct (2): 340

• Part Number: 163-23-3090


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color