162-23-7080 250 MCM 1C 37Strand Aluminum Shield 1/3 Neutral 133% EPR C
nassaunationalcable.com/es/products/162-23-7080-250-mcm-1c-37strand-aluminum-shield-1-3-neutral-133-epr-concentric-bc-pe-okoguard-uro-j-35kv-urd-cable

Items in Cart ()

View cart

162-23-7080 250 MCM 1C 37Strand Aluminum Shield 1/3 Neutral 133% EPR Concentric BC PE Okoguard URO-J 35KV URD Cable

162-23-7080 250 MCM 1C 37Strand Aluminum Shield 1/3 Neutral 133% EPR Concentric BC PE Okoguard URO-J 35KV URD Cable
Roll over image to Zoom

162-23-7080 250 MCM 1C 37Strand Aluminum Shield 1/3 Neutral 133% EPR Concentric BC PE Okoguard URO-J 35KV URD Cable

SKU: 162-23-7080
okoguard-aluminum-filled-strand-shield-neutral-epr-concentric-bc-pe-uro-j-35kv-urd-cable

Select a Gauge

162-23-7080 250 MCM 1C 37Strand Aluminum Shield 1/3 Neutral 133% EPR Concentric BC PE Okoguard URO-J 35KV URD Cable
Price:
Precio habitual
$0.00 /Qty
Precio de oferta
$0.00 /Qty
Los gastos de envío se calculan en la pantalla de pagos.
Free Shipping: On orders above $1000
La cantidad debe ser 1 o más

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

162-23-7080 250 MCM 1C 37Strand Aluminum Shield 1/3 Neutral 133% EPR Concentric BC PE Okoguard URO-J 35KV URD Cable

Allowable Ampacity for 162-23-7080 250 MCM 1C 37Strand Aluminum Shield 1/3 Neutral 133% EPR Concentric BC PE Okoguard URO-J 35KV URD Cable:100 Amps

About:

The cable is a high-voltage, single conductor (1C), aluminum shielded cable designed for utility distribution applications. It features a 1/3 neutral, 133% Ethylene Propylene Rubber (EPR) insulation, concentric Bare Copper (BC) shielding, and a Polyethylene (PE) Okoguard jacket. This cable is rated for 35KV Underground Residential Distribution (URD) systems.

Also Known As:

 Aluminum Shielded Cable
 35KV URD Cable
 Okoguard URO-J Cable

Application:

• Okoguard URO-J cables provide maximum circuit longevity in underground residential distribution systems. They can be buried directly or installed in underground ducts or conduits

Standards:

 ICEA S-94-649: Standard for Concentric Neutral Cables Rated 5 Through 46 KV
 AEIC CS8: Specification for extruded dielectric shielded power cables rated 5 through 46 KV
 UL 1072: Medium-Voltage Power Cables
 IEEE 383: Standard for Type Test of Class 1E Electric Cables, Field Splices, and Connections for Nuclear Power Generating Stations
 ASTM B609/B609M: Standard Specification for Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical Purposes

Construction:

• Central Conductor: Aluminum per ASTM B609, Class B stranded per B-231.
 Filled Strand: Water swellable agent meets or exceeds ICEA T-31-610 water penetration resistance and ANSI/NEMA Class A connectorability requirements.
 Conductor Screen: Extruded semiconducting ethylene-propylene rubber meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.
 Insulation: Extruded Okoguard meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.
• Insulation Screen: Extruded semiconducting ethylene-propylene rubber meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.
• Concentric Conductor: Bare copper concentric wires helically applied.
• Jacket: Black Okolene with 3 red extruded stripes meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5 for polyethylene jackets.

Features:

 Triple tandem extruded, all EPR system.
 Okoguard cables meet or exceed ICEA standards.
 Meets RUS 1728.204 for cables with filled strand or solid conductor and 133% insulation level.
 Improved Temperature Rating. Okoguard insulation system has been tested and qualified for operation at 105°C continuous and 140°C emergency operating temperature.
 250°C short circuit rating.
 Excellent corona resistance.
 Low dielectric constant and power factor.
 Screens are clean stripping.
 Exceptional resistance to "treeing".
 Moisture resistant.
 Excellent resistance to most chemicals.
 Can be listed by UL as Type MV-90 or MV-105 on special orders.
 CSA C68.5 listed, LTGG (-40°C), SR.
 Design Options:
 Triplexed or Paralleled
 Cable-in-Conduit
 Flat Strap Neutral
 Tinned Wires or Straps
 Water Blocking Powder or Tape
 Product identification via colored jackets

Specifications:

• Conductor Size AWG/kcmil: 250(37X)
• Nominal Dia. Over Insulation (in): 1.47
 Insulation Screen Thickness (miles): 40 
• Nominal Dia. Over Insulation Screen (in): 1.57
• Copper Neutral No. x AWG (1): 13X14
• Nominal O.D (in): 1.87
• Approx. Net Weight: 1653
• 90°C Ampacity Direct Burial (2): 305
• 90°C Ampacity Duct (2): 255
• 105°C Ampacity Direct Burial (2): 330
• 105°C Ampacity Duct (2): 285
• Part Number: 162-23-7080


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color

Download PDF Spec Sheet

Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460