160-23-3066 1 AWG 1C 19Strand Aluminum Shield 1/3 Neutral 133% EPR Con
nassaunationalcable.com/es/products/160-23-3066-1-awg-1c-19strand-aluminum-shield-1-3-neutral-133-epr-concentric-bc-pe-okoguard-uro-j-15kv-urd-cable

Items in Cart ()

View cart

160-23-3066 1 AWG 1C 19Strand Aluminum Shield 1/3 Neutral 133% EPR Concentric BC PE Okoguard URO-J 15KV URD Cable

160-23-3066 1 AWG 1C 19Strand Aluminum Shield 1/3 Neutral 133% EPR Concentric BC PE Okoguard URO-J 15KV URD Cable
Roll over image to Zoom

160-23-3066 1 AWG 1C 19Strand Aluminum Shield 1/3 Neutral 133% EPR Concentric BC PE Okoguard URO-J 15KV URD Cable

SKU: 160-23-3066
okoguard-strand-aluminum-shield-neutral-epr-concentric-bc-pe-uro-j-15kv-urd-cable

Select a Gauge

160-23-3066 1 AWG 1C 19Strand Aluminum Shield 1/3 Neutral 133% EPR Concentric BC PE Okoguard URO-J 15KV URD Cable
Price:
Precio habitual
$0.00 /Qty
Precio de oferta
$0.00 /Qty
Los gastos de envío se calculan en la pantalla de pagos.
Free Shipping: On orders above $1000
La cantidad debe ser 1 o más

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

160-23-3066 1 AWG 1C 19Strand Aluminum Shield 1/3 Neutral 133% EPR Concentric BC PE Okoguard URO-J 15KV URD Cable

Allowable Ampacity for 160-23-3066 1 AWG 1C 19Strand Aluminum Shield 1/3 Neutral 133% EPR Concentric BC PE Okoguard URO-J 15KV URD Cable:100 Amps

About:

This cable is a single conductor (1C), solid aluminum shielded cable, designed for underground residential distribution (URD) with a voltage rating of 15kV. It features an EPR (Ethylene Propylene Rubber) insulation with a concentric neutral design and a polyethylene (PE) Okoguard URO-J jacket.

Also Known As:

 EPR Insulated Aluminum Conductor Cable
 Okoguard URO-J PE Jacketed Cable

Application:

• Okoguard URO-J cables provide maximum circuit longevity in underground residential distribution systems. They can be buried directly or installed in underground ducts or conduits.

Standards:

 ANSI/ICEA S-94-649
 AEIC CS8
 UL 1072
 IEEE 404
 ASTM B609 (Aluminum conductor standards)

Construction:

• Central Conductor: Aluminum per ASTM B-609, Class B stranded per B-231.
 Conductor Screen: Extruded semiconducting ethylene-propylene rubber meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.
 Insulation: Extruded Okoguard meets or exceeds the requirements of ICEA S-94- 649, AEIC CS8, and CSA C68.5.
• Insulation Screen: Extruded semiconducting ethylene-propylene rubber meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and C68.5.
• Grounding Conductor: Where indicated, bare stranded copper per ASTM B-8 for sizes #7 AWG and smaller, compact round for sizes #8 AWG and larger per ASTM B-496 and in accordance with NEC Table 250.122
• Concentric Conductor: Bare copper wires.
• Jacket: Black Okolene with red extruded stripes meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5 for polyethylene jackets.

Features:

 Triple tandem extruded, all EPR system
 Okoguard cables meet or exceed ICEA standards.
 Meets RUS 1728.204 for cables with filled strand or solid conductor and 133% insulation level.
 105°C continuous operating temperature.
 140°C emergency rating.
 250°C short circuit rating.
 Excellent corona resistance.
 Low dielectric constant and power factor.
 Screens are clean stripping.
 Exceptional resistance to "treeing".
 Moisture resistant.
 Overall jacket provides extended life.
 Red extruded stripes.
 Excellent resistance to most chemicals.
 Can be listed by UL as Type MV-90 on Special Orders.
 CSA C68.5 listed, LTGG (-40 C), SR.
 Design Options:
 Additional conductor sizes
 Filled strand
 Copper central conductor
 Copper flat strap concentric neutral
 Product identification via colored jackets.
 Semiconducting jacket
 Improved Temperature Rating. Okoguard insulation system has been tested and qualified for operation at 105°C continuous and 140°C emergency operating temperature.
 Minimum installation temperature of -40°C.

Specifications:

• Conductor Size AWG/kcmil: 1(19X)
• Nominal Dia. Over Insulation (in): 0.81
 Insulation Screen Thickness (miles): 30
• Nominal Dia. Over Insulation Screen (in): 0.88
• Copper Neutral No. x AWG (1): 6X14
• Nominal O.D (in): 1.12
• Approx. Net Weight: 586
• 90°C Ampacity Direct Burial (2): 175
• 90°C Ampacity Duct (2): 140
• 105°C Ampacity Direct Burial (2): 185 
• 105°C Ampacity Duct (2): 150
• Part Number: 160-23-3066


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color

Download PDF Spec Sheet

Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460