16 AWG 12T Stranded Tinned Copper Shield Foil Braid Halogen-Free GAALS
nassaunationalcable.com/es/products/16-awg-12t-stranded-tinned-copper-shield-foil-braid-halogen-free-gaalship-bfouc-offshore-cable

Items in Cart ()

View cart

16 AWG 12T Stranded Tinned Copper Shield Foil Braid Halogen-Free GAALSHIP BFOU(c) Offshore Cable

16 AWG 12T Stranded Tinned Copper Shield Foil Braid Halogen-Free GAALSHIP BFOU(c) Offshore Cable
Roll over image to Zoom

16 AWG 12T Stranded Tinned Copper Shield Foil Braid Halogen-Free GAALSHIP BFOU(c) Offshore Cable

SKU: 14160C5X123M15

Select a Gauge

16 AWG 12T Stranded Tinned Copper Shield Foil Braid Halogen-Free GAALSHIP BFOU(c) Offshore Cable
Price:
Precio habitual
$0.00 /Qty
Precio de oferta
$0.00 /Qty
Los gastos de envío se calculan en la pantalla de pagos.
Free Shipping: On orders above $1000
La cantidad debe ser 1 o más

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

16 AWG 7T Stranded Tinned Copper Shield Foil Braid Halogen-Free GAALSHIP BFOU(c) Offshore Cable

Allowable Ampacity for 16 AWG 7T Stranded Tinned Copper Shield Foil Braid Halogen-Free GAALSHIP BFOU(c) Offshore Cable: 100 Amps

About:

This cable is designed for critical and demanding applications in marine and offshore environments, where safety and performance are paramount. It is constructed to withstand harsh conditions such as moisture, chemicals, extreme temperatures, and mechanical stresses.

Also Known As:

This type of cable may also be referred to by similar names that denote its specifications and uses, particularly in marine electrical systems.

Application:

 Offshore drilling rigs: For power and control systems where resistance to oil and environmental elements is necessary.
 Marine vessels: Used in shipboard telecommunications, control, and instrumentation applications.
 Harsh industrial environments: Suitable for installations where fire resistance and minimal smoke emissions are crucial.

Standards:

 BFOU(c) standard: This indicates compliance with fire resistance and low smoke zero halogen (LSZH) specifications tailored for offshore marine applications.
 International standards: Likely conforms to relevant IEC (International Electrotechnical Commission) standards for marine and offshore cables, ensuring safety and reliability.

Construction:

• Conductor: Stranded tinned copper conductor Cl. 2, acc. to IEC 60228
 Insulation: EPR, halogen-free compound + MICA glass tape acc.to IEC 60092-351, thickness acc. to IEC 60092-376
 Cores Color: pair: black- light blue, triple: black- light blue - brown
 Stranding: Cores lay-up in pairs, triples, laying-up of pairs, triples
 Screen: Overall screen, copper/polyester tape with tinned copper stranded drain wire and synthetic tape.
 Inner sheath: halogen-free compound Indicative thickness acc. to IEC 60092-376
 Armouring: Tinned copper wires braid acc. to IEC 60092-350

 Outer Sheath: grey (RAL 7001) halogen-free mud resistant thermosetting type SHF MUD, acc. to NEK IIII edit. 2009. thickness acc. to IEC 60092-376

Features:

 Sheathing materials acc. to: IEC 60092-359
 Insulating materials acc. to: IEC 60092-351
 Design guidelines acc. to: IEC 60092-350-376 / …-350 NEK 606 IIII ed 2009
 Choice and installation of electric cables acc. to: IEC 60092-352
 on request class 5
 on request halogen free thermosetting type SHF2 outer sheath, acc. to IEC 60092-359 and CSA 22.2 n.38-95 cold bend-impact test at low temperature (-40°C)
 acc. to NEK 606 IIII ed. 2009, Halogen free & MUD resistance cables, for the marine, ship and offshore
We have possibility to provide the following Certifications
on request:
 Det Norske Veritas (DNV)
 Lloyd’s Register (LR)

Specifications:

• No. of pairs/triples x cross section n x mm²: 12x3x1,5
• AWG no.: 16
• Ø under armour ca.mm ± 10%: 28,5 
• Outer-Ø ca.mm ± 10%: 33,8
• Nominal Voltage: Uo/U 150/250 V
• Temperature Range: - 40°C up to +90°C, Installation temp.: - 20 °C
• Short circuit temperature: +250°C
• Min. bending radius: 8 x D
• Cable Weight approx. kg/km: 1865
• Part Number: 14160C5X123M15


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color

Download PDF Spec Sheet

Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460