12 AWG 14C Bare Copper Unshielded Halogen-Free Sumsave® (AS) Z1Z1-K 0.6/1kV CPR Flexible Cable
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
12 AWG 14C Bare Copper Unshielded Halogen-Free Sumsave® (AS) Z1Z1-K 0.6/1kV CPR Flexible Cable
Allowable Ampacity for 12 AWG 14C Bare Copper Unshielded Halogen-Free Sumsave® (AS) Z1Z1-K 0.6/1kV CPR Flexible Cable: 100 Amps
Application:
Z1Z1-K (AS) CPR cables comply with the construction product classification criteria according to CPR Regulation 305/2011 and the EN 50575 standard, being those indicated for fixed installations, protected or not, where in case of fire it is required a low emission of smoke and corrosive gases, such as public places, hospitals, schools, shopping centers and airports. They are suitable for indoor and outdoor installations. Appropriate for installations where you want to increase fire protection.
Suitable for the following installations:
• ITC-BT 20 Interior or reception installations
• ITC-BT 28 Public premises
• ITC-BT 29 Installations in premises with risk of fire or explosion
• ITC-BT 30 Installations in premises with special characteristics
Also Known as:
Sumsave Cable, Sum Cable, Z1Z1-K Cable, Flexible Cable, Sumsave® (AS) Z1Z1-K Cable, CPR Cable
Design:
• Flexible electrolytic copper conductor (Class 5) according to UNE-EN 60228, EN 60228 and IEC 60228
• Halogen-free thermoplastic polyolefin insulation with characteristics according to Table 1 Annex 1 of the UNE 21123-4 / UNE-HD 603-4 standard Conductor
• identification according to UNE 21089, HD 308 S2 or EN 50334
• Thermoplastic polyolefin cover type DMZ-E according to UNE 21123-4 and UNE-HD 603-1 - ST8according to IEC 60502-1
• Green color
Technical Data:
Rated voltage 0.6/1 kV Test
voltage 3,500 V AC Maximum
temperature 70 °C
Minimum bending radius 6 x Outside diameter in fixed installation
Service temperature -40 °C to +70 °C
Specification:
AWG Size: 12
Number of Conductor: 14
Conductor: Bare Copper
N x S: 14G4 mm²
Conductor resistance at 20°C: 4.95 ohm/km
Outer Diameter approx: 21.90 mm
Rated Voltage: 0.6/1kV
Weight: 655.17 lbs/MFT
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460