12-3C Solid Copper MC-Stat® Plus Steel THHN Insulation Light Green Striped Interlocked Armored Cable
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
12-3C Solid Copper MC-Stat® Plus Steel THHN Insulation Light Green Striped Interlocked Armored CableAllowable Ampacity for 12-3C Solid Copper MC-Stat® Plus Steel THHN Insulation Light Green Striped Interlocked Armored Cable: 100 Amps
Applications:
Branch circuit wiring for a variety of power distribution systems from lighting, to devices and receptacles. Branch circuit to computers and other electronic equipment where additive harmonics currents from non-linear switching loads may be present
Also Known as:
AFC Cable, MC Cable, MC Stat Plus, Interlocked Armored, Interlocked Steel, Steel Cable, MCI-A Cable, Galvanized Interlocking, Steel Strip Cable, 120/208V Cable
Construction:
• Armor: Galvanized Interlocking Steel Strip (light green striped)
• Conductors: Solid Copper
• Conductor Insulation: Type THHN with Protective Polypropylene Covering on Each Insulated Conductor (No Assembly Tape)
• Neutral Conductor: White 120/208V
• Maximum Temperature Rating: 90°C (Dry)
• Maximum Voltage Rating: 600V
• Grounding: Two grounding means – (1) armor PLUS full-sized aluminum ground conductor, (2) Full-sized green insulated copper grounding conductor NEC® 250.118(10)(b)
Features & Benefits:
• A neutral per phase Type MCI-A cable designed for multi-wire branch circuit applications
• Addresses harmonics distortions in power distribution systems and meets the requirements of NEC® 210.4(B) Disconnecting Means
• Eliminates shared neutrals and allows electrical systems to continue to operate
Decreases the time it takes to identify a faulty circuit because only the affected single-phase breaker will trip thus, reducing the length of unnecessary outages
• Type MCI-A cable with a green insulated copper grounding conductor
• Made in USA of US and/or imported materials
References & Ratings:
• UL 1569, UL 83, UL 1479, UL 1581, UL 2556, E80042
• Federal spec A-A–59544 (formerly J-C–30B)
• NEC® 210.4(B), 330, 300.22(C), 230.43, 250.118, 392, 396, 503, 530, 517, 518, 530, 645
• Meets all OSHA and HUD requirements
• May be surface mounted, fished, and/or embedded in plaster
• UL Classified 1, 2, and 3 hours through (Fire) penetration product, R–14141
• NEC® 300.22(C) Environmental Air Handling Spaces
• Cable Tray Rated, install per NEC®
• Patent Pending
• Made in USA of US and/or imported materials
Specification:
• Phase AWG Size: 12
• Number of Conductors: 3
• Neutral AWG Size: 12
• Number of Conductors: 3
• Insulated Grounding Wire AWG: 12 (Solid Green)
• Bonding/Bond Cond. AWG: 10
• Armor Nominal O.D: 0.663 Inch
• Weight 1000ft: 327 Lbs
• (Black / Red / Blue) 1000' Reel Code: 7005-60-00
*Data provided on this page is subject to change based on different manufacturers' variances