115-23-3446 350 MCM 1C Stranded Bare Copper Tape Shield EPR Okoguard Okoseal PVC MV-105 420mils 35KV Power Cable
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
115-23-3446 350 MCM 1C Stranded Bare Copper Tape Shield EPR Okoguard Okoseal PVC MV-105 420mils 35KV Power Cable
Allowable Ampacity for 115-23-3446 350 MCM 1C Stranded Bare Copper Tape Shield EPR Okoguard Okoseal PVC MV-105 420mils 35KV Power Cable:100 Amps
About:
The 115-23-3446 350 MCM 1C Stranded Bare Copper Tape Shield EPR Okoguard Okoseal PVC MV-105 420mils 35KV Power Cable is a robust high-voltage power cable designed for demanding applications. It features a stranded bare copper conductor for flexibility and durability, Ethylene Propylene Rubber (EPR) insulation for excellent heat resistance, and an Okoseal PVC jacket for additional protection. The copper tape shield helps prevent electrical interference and enhances safety.
Also Known As:
• High-Voltage Power Cable
• MV-105 35KV Cable
• EPR Insulated Power Cable
• Copper Tape Shielded Power Cable
Applications:
• Okoguard shielded Okoseal Type MV-105 power cables are recommended for use as
feeder circuits, in electric utility generating stations, for distribution circuits, and for
feeders or branch circuits in industrial and commercial installations.
• Type MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to
sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 250.4(A)(5) and 315.36, or messenger supported in industrial establishments and electric utilities.
• Sizes 1/0 AWG and larger may also beinstalled in cable tray
Standards:
• UL Certification: Assures compliance with safety and quality standards.
• IEC Standards: Meets international safety and performance criteria for medium-voltage cables.
• IEEE Standards: Complies with Institute of Electrical and Electronics Engineers guidelines for high-voltage cables.
• NEMA Compliance: Meets National Electrical Manufacturers Association standards for electrical equipment.
Construction:
• Conductor: Annealed uncoated copper compact stranded per ASTM B-496.
• Strand Screen: Extruded EPR semiconducting strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639/NEMA WC74 & S-97-682,
AEIC CS8, CSA C68.10 and UL 1072.
• Insulation: Meets or exceeds electrical and physical requirements of ICEA S-93- 639/NEMA WC74 & S-97-682, AEIC CS8, CSA C68.10 and UL 1072.
• Insulation Screen: Extruded EPR semiconducting insulation screen applied directly over the insulation. Meets or exceeds electrical and physical requirements of ICEA
S-93-639/NEMA WC74 & S-97-682, AEIC CS8, CSA C68.10 and UL 1072.
• Shield: 5 mil bare copper tape helically applied with 25% minimum overlap.
• Jacket: Meets or exceeds electrical and physical requirements of ICEA S-93-
639/NEMA WC74 & S-97-682, CSA C68.10 and UL 1072 for polyvinyl chloride jackets.
UL listed as Type MV-105, sunlight resistant, and for use in cable tray in accordance with UL 1072.
CSA C68.10 listed as FT4, SR, LTGG (-40°C), TC (< 500 kcmil) and TC-ER ( 500 kcmil).
Features:
• Triple tandem extruded, all EPR system.
• Okoguard cables meet or exceed all recognized industry standards (UL, CSA, AEIC, NEMA/ICEA, IEEE).
• 105°C continuous operating temperature.
• 140°C emergency rating.
• 250°C short circuit rating.
• Passes the Vertical Tray Flame Test requirements of UL 1072 and IEEE 383 and 1202.
• Excellent corona resistance.
• Screens are clean stripping.
• Exceptional resistance to "treeing".
• Exceptional resistance to moisture.
• Resistant to most oils, acids, and alkalies.
• Sunlight resistant.
• For Cable Tray Use.
• Improved Temperature Rating.
Specifications:
• Conductor Size AWG: 350 MCM
• Conduit Size Inches (5): 5
• Approx. Dia. over Insulation (in.): 1.53
• Jacket Thickness (mm): 2.79
• Approx. O.D. (Inches): 1.84
• Approx. Net Weight: 2540
• Ampacities Conduit in Air (2 ): 440
• Ampacities Underground Duct (3): 415
• Ampacities Cable Tray (4): 610
• Part Number: 115-23-3446
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460