114-23-3060 350 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 5/8KV Power Cable
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
114-23-3060 350 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 5/8KV Power Cable
Allowable Ampacity for 114-23-3060 350 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 5/8KV Power Cable:100 Amps
About:
This specific cable model, designated as 114-23-3060, features a 350 MCM stranded uncoated copper conductor, ensuring efficient power transmission and flexibility for installation. It is insulated with Okoguard, Okonite's proprietary ethylene-propylene rubber (EPR) compound, and protected by a copper shield and an Okoclear-TP outer jacket. The MV-105 classification indicates its suitability for medium voltage applications up to 5/8 kilovolts, designed to provide reliable and safe power.
Also Known As:
• 350 MCM MV-105 Okoguard Cable
• Medium Voltage Copper Power Cable
• 5/8kV Stranded Copper Okoclear Cable
Applications:
• Okoguard Shielded Okoclear-tp Type Mv-105 Power Cables Are Recommended For Use As Feeder Circuits, In Electric Utility Generating Stations, For Distribution Circuits, And For Feeders Or Branch Circuits In Industrial And Commercial Installations, Where A Cable With Low Smoke/zero Halogen Characteristics Is Needed.
• Type Mv Cables May Be Installed In Wet Or Dry Locations, Indoors Or Outdoors (Exposed
To Sunlight), In Any Raceway Or Underground Duct, Directly Buried If Installed In A System With A Grounding Conductor In Close Proximity That Conforms With Nec Section 250.4(A)(5), And 315.36 Or Messenger Supported In Industrial Establishments And Electric Utilities.
• May Be Installed In Cable Trays Where Permitted By Nec Section 315.32(3).
Standards:
• IEEE 1202 or UL 1685 (Vertical Tray Flame Tests) for fire resistance
• ICEA S-93-639/NEMA WC 74 for medium voltage power cables
• UL 1072 for medium voltage power cables
Construction:
• Conductor: Uncoated copper compact stranded per ASTM B-496.
• Strand Screen: Extruded semiconducting EPR strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, AEIC CS8, and UL 1072.
• Insulation: Meets or exceeds electrical and physical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, AEIC CS8, and UL 1072.
• Insulation Screen: Extruded semiconduction EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, AEIC CS8, and UL 1072.
• Shield: 5 mil bare copper tape helically applied, with 25% minimum overlap.
• Jacket: Meets or exceeds electrical and physical requirements of ICEA S-93-639
for Type I thermoplastic polyolefin jackets. UL listed as Type MV-105, sunlight resistant and for use in cable tray in
accordance with UL 1072.
Features:
• Low smoke/zero halogen jacket.
• Low smoke/zero halogen jacket.
• Okoguard cables meet or exceed all recognized industry standards (UL, NEMA/ICEA and IEEE).
• Triple tandem extruded, all EPR system.
• 105°C continuous operating temperature.
• 140°C emergency rating.
• 250°C short circuit rating
• Excellent corona resistance.
• Exceptional resistance to “treeing”.
• Screens are clean stripping.
• Exceptional resistance to moisture.
• Resistant to most oils, acids, and alkalis.
• UL listed: MV-105, Sunlight Resistant, and Cable Tray Use.
• Passes the UL & IEEE 383-1974 Vertical Tray Flame Test.
• Sizes 500 kcmil and larger pass FT4/IEEE 1202 Vertical Tray Flame Test.
Specifications:
• Conductor Size AWG: 350 MCM
• Conduit Size Inches (5): 3 1/2
• Approx. Dia. over Insulation (in.): 0.89
• Jacket Thickness (mm): 2.03
• Approx. O.D. (Inches): 1.21
• Approx. Net Weight: 1575
• Ampacities (2) Conduit in Air: 440
• Ampacities (3) Underground Duct: 415
• Ampacities (4) Cable Tray: 610
• Part Number: 114-23-3060
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet
Reviews