112-31-6404 4 AWG 3C Strand 3#12 Gnd Bare Copper Shield X-Olene Okoseal Binder Tape PVC 600/1000V VFD Cable
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
112-31-6404 4 AWG 3C Strand 3#12 Gnd Bare Copper Shield X-Olene Okoseal Binder Tape PVC 600/1000V VFD Cable
Allowable Ampacity for 112-31-6404 4 AWG 3C Strand 3#12 Gnd Bare Copper Shield X-Olene Okoseal Binder Tape PVC 600/1000V VFD Cable:100 Amps
About:
This cable is designed for variable frequency drive (VFD) applications. It is constructed with a bare copper shield, X-Olene binder tape, and Okoseal PVC insulation, ensuring robust performance and durability in industrial environments. The cable is rated for 600/1000V and is engineered to handle the unique electrical challenges of VFD systems, such as high-frequency noise and voltage spikes.
Also Known As:
• VFD Cable
• 600/1000V VFD Cable
• Okoseal VFD Cable
Application:
• X-Olene shielded Type TC-ER cables are used to supply power to motors from variable frequency drives, where an economical design is desired. These cables can also be used for other power, lighting, control or signal circuits; indoors or outdoors; in cable trays, raceways, direct burial, or where supported by messenger wire; for Class 1 circuits as permitted in Article 725 of the NEC; and in cable trays in Class I, Division 2 hazardous locations in industrial establishments where the conditions of maintenance and supervision assure that only qualified persons will service the installation. Cables marked TC-ER may also be used between a cable tray and the utilization equipment or device, when installed in accordance with NEC 336.10(7).
Standards:
• UL 1277: Electrical Power and Control Tray Cables with Optional Optical-Fiber Members
• UL 1685: Standard for Vertical-Tray Fire-Propagation and Smoke-Release Test for Electrical and Optical-Fiber Cables
• IEEE 1202: Standard for Flame Testing of Cables for Use in Cable Tray in Industrial and Commercial Occupancies
• ICEA T-29-520: Vertical Cable Tray Flame Test
Construction:
• Conductor: Uncoated soft copper perASTM B3. Sizes smaller than 8 AWG are compressed stranded per ASTM B-8. Sizes 8 AWG and larger are compact stranded perASTM B-496.
• Insulation: X-Olene per ICEA S-95-658/ NEMA WC70 and UL44, Listed ULType XHHW-2.
• Conductor Identification: Sizes 14, 12 and 10 AWG color-coded insulation per ICEA S-73- 532/NEMA WC57 Method 1, Table E-2 color sequence. Sizes 8 AWG and larger black insulation with surface printing of numbers and colors per ICEA S-73 532/NEMA WC57 Method 3, Table E-2.
• Grounding Conductor(s): Three bare soft copper perASTM B-3. Sizes 10AWG and smaller are compressed stranded per ASTM B-8, and sizes 8 AWG and larger are compact stranded per ASTM B-496. Meets or exceeds requirements of NEC Table 250.122.
• Shield: A 5 mil bare copper tape is helically applied with 25% minimum overlap.
• Jacket: The Okoseal (PVC) compound meets and exceeds the requirements of UL 1277 as tested in accordance with UL1581.
Features:
• Insulated conductors are UL Listed Type XHH/XHHW-2.
• 90°C continuous rating in wet and dry locations.
• 130°C emergency overload rating.
• 250°C short circuit rating.
• Three symmetrical grounding conductors and a helically applied copper tape provide a relatively low resistance return path, adequate for VFD and other modern AC drive/motor applications.
• Type TC-ER VFD cables are quality control inspected to meet or exceed applicable industry standards.
• Thermal stability at elevated temperatures.
• Mechanically rugged.
• High dielectric strength.
• Small diameter, lightweight.
• Minimum installation temperature of -40°C.
Specifications:
• Conductor Size AWG/kcmil: 4(7X)
• Insulation Thickness (miles): 45
• Grounding Conductor(s) AWG: 3#12
• Jacket Thickness (miles): 60
• Jacket Thickness (mm): 1.52
• Approx. O.D (in): 0.821
• Approx. O.D (mm): 20.85
• Approx. Cross Sectional Area (sq. in): 0.53
• Approx. Net Weight: 676
• 90°C Wet or Dry NEC Ampacity (1): 95
• 75°C Wet or NEC Ampacity (1): 85
• Part Number: 112-31-6404
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color